Browse hierarchy: [General Hospital (HO)](/submissions/HO) → [Subpart G — General Hospital and Personal Use Miscellaneous Devices](/submissions/HO/subpart-g%E2%80%94general-hospital-and-personal-use-miscellaneous-devices) → [21 CFR 880.6511](/submissions/HO/subpart-g%E2%80%94general-hospital-and-personal-use-miscellaneous-devices/880.6511) → SCS — Ultraviolet Radiation Disinfection Chamber Device

# SCS · Ultraviolet Radiation Disinfection Chamber Device

_General Hospital · 21 CFR 880.6511 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/SCS

## Overview

- **Product Code:** SCS
- **Device Name:** Ultraviolet Radiation Disinfection Chamber Device
- **Regulation:** [21 CFR 880.6511](/submissions/HO/subpart-g%E2%80%94general-hospital-and-personal-use-miscellaneous-devices/880.6511)
- **Device Class:** 2
- **Review Panel:** [General Hospital](/submissions/HO)

## Identification

An ultraviolet radiation disinfection chamber device is intended to disinfect patient contacting medical devices using UV radiation after the device has been cleaned. Disinfection of the medical device is achieved within an enclosed chamber through the exposure to UV radiation. The Germitec Chronos® is an automated medical device consisting of a sealed disinfection chamber, incorporating multiple UV-C lamps and reflective walls, indicated for use in a healthcare environment to achieve a high-level disinfection of surfaces of external, transvaginal, and transrectal ultrasound probes that do not contain lumens and that do not contain indentations or channels that are deeper than their widths.

## Classification Rationale

Class II (special controls). The device is granted under the De Novo process, and the probable benefits outweigh the risks, which can be mitigated by the use of general controls and the identified special controls.

## Special Controls

In combination with the general controls of the FD&C Act, the ultraviolet radiation disinfection chamber device is subject to the following special controls:

## Recent Cleared Devices (2 of 2)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K251354](/device/K251354.md) | UV Smart D60 | UV Smart Technologies B.V. | Jan 29, 2026 | SESE |
| [DEN230067](/device/DEN230067.md) | Chronos® | Germitec | Aug 28, 2024 | DENG |

## Top Applicants

- Germitec — 1 clearance
- UV Smart Technologies B.V. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/SCS](https://fda.innolitics.com/productcode/SCS)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).