Browse hierarchy: [Orthopedic (OR)](/submissions/OR) → [Subpart D — Prosthetic Devices](/submissions/OR/subpart-d%E2%80%94prosthetic-devices) → [21 CFR 888.3071](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/888.3071) → QZY — Spinal Fusion System With 12-Methacryloyloxydodecyl Pyridinium Bromide (C21h34brno2) Coating

# QZY · Spinal Fusion System With 12-Methacryloyloxydodecyl Pyridinium Bromide (C21h34brno2) Coating

_Orthopedic · 21 CFR 888.3071 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/QZY

## Overview

- **Product Code:** QZY
- **Device Name:** Spinal Fusion System With 12-Methacryloyloxydodecyl Pyridinium Bromide (C21h34brno2) Coating
- **Regulation:** [21 CFR 888.3071](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/888.3071)
- **Device Class:** 2
- **Review Panel:** [Orthopedic](/submissions/OR)
- **Implant:** yes

## Identification

A spinal fusion device with quaternary ammonium coating is a rigid metallic implant device or system comprised of single or multiple components intended to facilitate fusion in skeletally mature patients. The device includes a quaternary ammonium compound coating that is covalently bonded to the device. Where applied, the coating is intended to reduce microbial contamination on the surface of the device prior to implantation. The device does not contain antimicrobial agents that act within or on the body and this device type does not include combination products.

## Classification Rationale

Class II (special controls). The device is granted under the De Novo process, and the risks can be mitigated by the use of general controls and the identified special controls.

## Special Controls

In combination with the general controls of the FD&C Act, the spinal fusion device with quaternary ammonium compound coating is subject to the following special controls:

## Recent Cleared Devices (1 of 1)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [DEN220015](/device/DEN220015.md) | Orthobond Mariner Pedicle Screw System | Orthobond Coporation | Apr 5, 2024 | DENG |

## Top Applicants

- Orthobond Coporation — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/QZY](https://fda.innolitics.com/productcode/QZY)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).