Browse hierarchy: [Cardiovascular (CV)](/submissions/CV) → [Subpart F — Cardiovascular Therapeutic Devices](/submissions/CV/subpart-f%E2%80%94cardiovascular-therapeutic-devices) → [21 CFR 870.5720](/submissions/CV/subpart-f%E2%80%94cardiovascular-therapeutic-devices/870.5720) → QXV — Temperature Regulation Device For Esophageal Protection During Cardiac Ablation

# QXV · Temperature Regulation Device For Esophageal Protection During Cardiac Ablation

_Cardiovascular · 21 CFR 870.5720 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/QXV

## Overview

- **Product Code:** QXV
- **Device Name:** Temperature Regulation Device For Esophageal Protection During Cardiac Ablation
- **Regulation:** [21 CFR 870.5720](/submissions/CV/subpart-f%E2%80%94cardiovascular-therapeutic-devices/870.5720)
- **Device Class:** 2
- **Review Panel:** [Cardiovascular](/submissions/CV)

## Identification

The ensoETM is a multi-lumen silicone tube placed in the esophagus to connect to an external heat exchanger to either cool or warm a patient or to cool the esophagus to reduce the likelihood of thermal injury after radiofrequency (RF) cardiac ablation procedures. It also provides gastric decompression and suctioning.

## Classification Rationale

Class II (special controls). The device is a temperature regulation device for esophageal protection during cardiac ablation procedures, and the FDA has determined that the benefits outweigh the risks when mitigated by the use of class II controls.

## Special Controls

In combination with the general controls of the FD&C Act, the temperature regulation device for esophageal protection during cardiac ablation procedures device is subject to the following special controls:

## Recent Cleared Devices (1 of 1)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [DEN230021](/device/DEN230021.md) | ensoETM | Advanced Cooling Therapy, Inc. D/B/A Attune Medical | Sep 13, 2023 | DENG |

## Top Applicants

- Advanced Cooling Therapy, Inc. D/B/A Attune Medical — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/QXV](https://fda.innolitics.com/productcode/QXV)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
