Browse hierarchy: [Immunology (IM)](/submissions/IM) → [Subpart G — Tumor Associated Antigen Immunological Test Systems](/submissions/IM/subpart-g%E2%80%94tumor-associated-antigen-immunological-test-systems) → [21 CFR 866.6010](/submissions/IM/subpart-g%E2%80%94tumor-associated-antigen-immunological-test-systems/866.6010) → QXS — Chromogranin A

# QXS · Chromogranin A

_Immunology · 21 CFR 866.6010 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/QXS

## Overview

- **Product Code:** QXS
- **Device Name:** Chromogranin A
- **Regulation:** [21 CFR 866.6010](/submissions/IM/subpart-g%E2%80%94tumor-associated-antigen-immunological-test-systems/866.6010)
- **Device Class:** 2
- **Review Panel:** [Immunology](/submissions/IM)

## Identification

A tumor-associated antigen immunological test system is a device that consists of reagents used to qualitatively or quantitatively measure, by immunochemical techniques, tumor-associated antigens in serum, plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease.

## Classification Rationale

Class II (special controls). Tumor markers must comply with the following special controls: (1) A guidance document entitled “Guidance Document for the Submission of Tumor Associated Antigen Premarket Notifications (510(k)s) to FDA,” and (2) voluntary assay performance standards issued by the National Committee on Clinical Laboratory Standards.

## Special Controls

*Classification.* Class II (special controls). Tumor markers must comply with the following special controls: (1) A guidance document entitled “Guidance Document for the Submission of Tumor Associated Antigen Premarket Notifications (510(k)s) to FDA,” and (2) voluntary assay performance standards issued by the National Committee on Clinical Laboratory Standards.

## Recent Cleared Devices (1 of 1)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K222251](/device/K222251.md) | B·R·A·H·M·S CgA II KRYPTOR, B·R·A·H·M·S CgA II KRYPTOR CAL, B·R·A·H·M·S CgA II KRYPTOR QC | B.R.A.H.M.S GmbH, Part of Thermo Fisher | Sep 18, 2023 | SESE |

## Top Applicants

- B.R.A.H.M.S GmbH, Part of Thermo Fisher — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/QXS](https://fda.innolitics.com/productcode/QXS)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com