Browse hierarchy: [General Hospital (HO)](/submissions/HO) → [Subpart F — General Hospital and Personal Use Therapeutic Devices](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices) → [21 CFR 880.5570](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/880.5570) → QNS — Low Dead Space Needle, Single Lumen, Hypodermic

# QNS · Low Dead Space Needle, Single Lumen, Hypodermic

_General Hospital · 21 CFR 880.5570 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/QNS

## Overview

- **Product Code:** QNS
- **Device Name:** Low Dead Space Needle, Single Lumen, Hypodermic
- **Regulation:** [21 CFR 880.5570](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/880.5570)
- **Device Class:** 2
- **Review Panel:** [General Hospital](/submissions/HO)

## Identification

A hypodermic single lumen needle is a device intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. The device consists of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.

## Classification Rationale

Class II (performance standards).

## Recent Cleared Devices (3 of 3)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K242956](/device/K242956.md) | LDS Needle; OcuSafe® LDS Needle; SteriCap® LDS Safety Needle; VitreJect® LDS Safety Needle | Ocuject, LLC | Oct 25, 2024 | SESE |
| [K231734](/device/K231734.md) | STERiJECT Low Dead Space, STERiJECT The Invisible Needle | Tsk Laboratory International Japan KK | Mar 8, 2024 | SESE |
| [K210444](/device/K210444.md) | EZ-Injec LDV Sterile Safety Needle | Poonglim Pharmatech, Inc. | Feb 16, 2021 | SESE |

## Top Applicants

- Ocuject, LLC — 1 clearance
- Poonglim Pharmatech, Inc. — 1 clearance
- Tsk Laboratory International Japan KK — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/QNS](https://fda.innolitics.com/productcode/QNS)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
