Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5330](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5330) → QAJ — Cutaneous Electrode Stimulator For Urinary Incontinence

# QAJ · Cutaneous Electrode Stimulator For Urinary Incontinence

_Gastroenterology, Urology · 21 CFR 876.5330 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/QAJ

## Overview

- **Product Code:** QAJ
- **Device Name:** Cutaneous Electrode Stimulator For Urinary Incontinence
- **Regulation:** [21 CFR 876.5330](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5330)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)

## Identification

A transcutaneous electrical continence device consists of cutaneous electrodes that are used to apply external stimulation to reduce urinary incontinence.

## Classification Rationale

Class II (special controls). The special controls for this device are:

## Special Controls

In combination with the general controls of the FD&C Act, the transcutaneous electrical continence device is subject to the following special controls:

*Classification.* Class II (special controls). The special controls for this device are:(1) Non-clinical performance testing must characterize the electrical stimulation, including the following: Waveforms, output modes, maximum output voltage, maximum output current, pulse duration, frequency, net charge per pulse, maximum phase charge at 500 ohms, maximum current density, maximum average current, and maximum average power density.
(2) The patient-contacting materials must be demonstrated to be biocompatible.
(3) Performance data must demonstrate the electromagnetic compatibility (EMC), electrical safety, thermal safety, and mechanical safety of the device.
(4) Software verification, validation, and hazard analysis must be performed.
(5) Labeling must include the following:
(i) Instructions for use, including specific instructions regarding the proper placement of electrodes;
(ii) A summary of electrical stimulation parameters; and
(iii) Cleaning instructions and reuse information.

## Recent Cleared Devices (5 of 5)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K253285](/device/K253285.md) | Elitone for Men | Elidah, Inc. | Jan 23, 2026 | SESE |
| [K223884](/device/K223884.md) | ELITONE Urge Urinary Incontinence Device | Elidah, Inc. | Feb 24, 2023 | SESE |
| [K192357](/device/K192357.md) | INNOVO | Atlantic Therapeutics, Ltd. | Jan 16, 2020 | SESE |
| [K183585](/device/K183585.md) | Elitone Device | Elidah, Inc. | Feb 11, 2019 | SESE |
| [DEN170049](/device/DEN170049.md) | Innovo | Bio-Medical Research, Ltd. | Nov 6, 2018 | DENG |

## Top Applicants

- Elidah, Inc. — 3 clearances
- Atlantic Therapeutics, Ltd. — 1 clearance
- Bio-Medical Research, Ltd. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/QAJ](https://fda.innolitics.com/productcode/QAJ)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
