Browse hierarchy: [General Hospital (HO)](/submissions/HO) → [Subpart F — General Hospital and Personal Use Therapeutic Devices](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices) → [21 CFR 880.5440](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/880.5440) → PYR — Neuraxial Administration Set - Intrathecal Delivery

# PYR · Neuraxial Administration Set - Intrathecal Delivery

_General Hospital · 21 CFR 880.5440 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/PYR

## Overview

- **Product Code:** PYR
- **Device Name:** Neuraxial Administration Set - Intrathecal Delivery
- **Regulation:** [21 CFR 880.5440](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/880.5440)
- **Device Class:** 2
- **Review Panel:** [General Hospital](/submissions/HO)

## Identification

An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.

## Classification Rationale

Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

## Special Controls

*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

## Recent Cleared Devices (0 of 0)

_No cleared devices on record._

---

**Source:** [https://fda.innolitics.com/productcode/PYR](https://fda.innolitics.com/productcode/PYR)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
