PNG · Peritoneal, Drainage Catheter For Refractory Ascites, Long-Term Indwelling

Gastroenterology, Urology · 21 CFR 876.5630 · Class 2

Overview

Product CodePNG
Device NamePeritoneal, Drainage Catheter For Refractory Ascites, Long-Term Indwelling
Regulation21 CFR 876.5630
Device ClassClass 2
Review PanelGastroenterology, Urology
ImplantYes
Life-SustainingYes

Identification

(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.

Classification Rationale

Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

Special Controls

*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

Recent Cleared Devices (15 of 15)

RecordDevice NameApplicantDecision DateDecision
K241278ASEPT® Glide Peritoneal Drainage SystemPfm Medical, Inc.Jan 14, 2025SESE
K241946PeritX™ 1L Drainage Kit (90-1010); PeritX™ 2L Drainage Kit (90-2010); PeritX™ Peritoneal Catheter Kit (50-9000C); PeritX™ Peritoneal Catheter and Starter Kit (50-9900C); PeritX™ Peritoneal Catheter Mini Kit (50-9050A); PleurX™ Low Profile Catheter Mini Kit (50-8050); Valve Cap (50-7235A); PeritX™ Valve Kit (50-7272); Catheter Access Kit (50-7280A); Lockable Drainage Line (50-7245A); Lockable Drainage Line Kit (50-7265A); PleurX™ Supplemental Insertion Kit (50-7262); Procedure Pack (50-Bard Peripheral Vascular, Inc.Dec 6, 2024SESE
K230319Passio Pump Drainage SystemBearpac MedicalNov 24, 2023SESK
K221779ASEPT Peritoneal Drainage SystemPfm Medical, Inc.May 2, 2023SESK
K212675Aspira Peritoneal Drainage SystemMerit Medical Systems, Inc.Dec 14, 2021SESK
K201155PleurX Peritoneal Catheter SystemCare FusionOct 21, 2020SESK
K162457Rocket Indwelling Peritoneal Catheter (IPC) Insertion KitRocket Medical PlcNov 14, 2016SEKD
K160437PleurX Peritoneal Catheter SystemCare FusionNov 3, 2016SEKD
K152105Rocket IPC Insertion Set, Rocket IPC Mini Insertion SetRocket Medical PlcMar 29, 2016SESK
K122422PLEURX PLEURAL CATHETER SYSTEM PLEURX CATHETER ACCESS KIT PLEURX SLIDE VALVED PEELABLE INTRODUCERCare FusionOct 24, 2012SESK
K113854PLEURX PERITONEAL CATHETER SYSTEMCare FusionMar 19, 2012SESK
K110396ASPIRA PERITONEAL DRAINAGE SYSTEMC.R. Bard, Inc.May 6, 2011SESE
K093796ASEPT PERITONEAL DRAINAGE SYSTEMPfm Medical, Inc.Feb 26, 2010SESK
K081288ASPIRA PERITONEAL DRAINAGE SYSTEMC.R. Bard, Inc.Jul 18, 2008SESE
K051711PLEURX PERITONEAL CATHETER KIT AND PLEURX DRAINAGE KITSDenver Biomedical, Inc.Nov 15, 2005SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...