Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5980](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5980) → PIO — Enteral Specific Transition Connectors

# PIO · Enteral Specific Transition Connectors

_Gastroenterology, Urology · 21 CFR 876.5980 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/PIO

## Overview

- **Product Code:** PIO
- **Device Name:** Enteral Specific Transition Connectors
- **Regulation:** [21 CFR 876.5980](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5980)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)

## Identification

A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use).

## Classification Rationale

(1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.

## Special Controls

*Classification.* (1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.

## Recent Cleared Devices (9 of 9)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K231299](/device/K231299.md) | Nutricair enteral ENFit adapter: ENFit male – stepped/Christmas tree connector | Cair Lgl | Jan 22, 2024 | SESE |
| [K233190](/device/K233190.md) | ENFit Adaptor | Jiangsu Caina Medical Co.,Ltd | Jan 18, 2024 | SESE |
| [K220165](/device/K220165.md) | Enteral Transition Adaptor | GBUK Group, Ltd. | Oct 21, 2022 | SESE |
| [K162254](/device/K162254.md) | Cedic Enteral ENFit Transition Connectors | Cedic S.R.L. | May 4, 2017 | SESE |
| [K151237](/device/K151237.md) | Nutrisafe 2- ENFit Adaptor | Vygon | Feb 9, 2016 | SESE |
| [K151628](/device/K151628.md) | Medline ENFit Connectors | Medline Industries, Inc. | Jul 24, 2015 | SESE |
| [K150034](/device/K150034.md) | AMT Enteral Transition Adapters | Applied Medical Technology, Inc. | Jun 9, 2015 | SESE |
| [K150010](/device/K150010.md) | Cedic Oral/Luer Enteral ENFit Transition Connector for Medication Port | Cedic S.R.L. | Apr 2, 2015 | SESE |
| [K140581](/device/K140581.md) | CEDIC ENTERAL DISTAL END ENFIT TRANSITION CONNECTOR, CEDIC ENTERAL ENFIT TRANSITION CONNECTOR FOR MEDICATION PORT | Cedic S.R.L. | Oct 17, 2014 | SESE |

## Top Applicants

- Cedic S.R.L. — 3 clearances
- Applied Medical Technology, Inc. — 1 clearance
- Cair Lgl — 1 clearance
- GBUK Group, Ltd. — 1 clearance
- Jiangsu Caina Medical Co.,Ltd — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/PIO](https://fda.innolitics.com/productcode/PIO)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com