Browse hierarchy: [Microbiology (MI)](/submissions/MI) → [Subpart D — Serological Reagents](/submissions/MI/subpart-d%E2%80%94serological-reagents) → [21 CFR 866.3361](/submissions/MI/subpart-d%E2%80%94serological-reagents/866.3361) → PEX — System, Mass Spectrometry, Maldi Tof, Microorganism Identification, Cultured Isolates

# PEX · System, Mass Spectrometry, Maldi Tof, Microorganism Identification, Cultured Isolates

_Microbiology · 21 CFR 866.3361 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/PEX

## Overview

- **Product Code:** PEX
- **Device Name:** System, Mass Spectrometry, Maldi Tof, Microorganism Identification, Cultured Isolates
- **Regulation:** [21 CFR 866.3361](/submissions/MI/subpart-d%E2%80%94serological-reagents/866.3361)
- **Device Class:** 2
- **Review Panel:** [Microbiology](/submissions/MI)

## Identification

A mass spectrometer system for clinical use for the identification of microorganisms is a qualitative in vitro diagnostic device intended for the identification of microorganisms cultured from human specimens. The device is comprised of an ionization source, a mass analyzer, and a spectral database. The device is indicated for use in conjunction with other clinical and laboratory findings to aid in the diagnosis of bacterial and fungal infections.

## Classification Rationale

Class II (special controls). The special controls for this device are:

## Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) Premarket notification submissions must include detailed documentation for device software, including, but not limited to, standalone software applications and hardware-based devices that incorporate software.
(2) Premarket notification submissions must include database implementation methodology, construction parameters, and quality assurance protocols.
(3) A detailed explanation of the interpretation of results and acceptance criteria must be included in the device's 21 CFR 809.10(b)(9) compliant labeling.
(4) As part of the risk management activities performed under 21 CFR 820.10(c) design and development, you must document an appropriate end user device training program that will be offered as part of your efforts to mitigate the risk of failure to correctly operate the instrument.
(5) Premarket notification submissions must include details on the appropriate end user device training program that will be offered while marketing the device.

## Recent Cleared Devices (5 of 5)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K163536](/device/K163536.md) | MALDI Biotyper CA (MBT-CA) System, MBT smart CA System | Bruker Daltonik GmbH | Jul 26, 2017 | SESE |
| [K162950](/device/K162950.md) | VITEK MS | bioMerieux, Inc. | Jul 22, 2017 | SESE |
| [K142677](/device/K142677.md) | MALDI Biotyper CA System | Bruker Daltonics, Inc. | Mar 27, 2015 | SESE |
| [K130831](/device/K130831.md) | MALDI BIOTYPER CA (MBT-CA) SYSTEM | Bruker Daltonics, Inc. | Nov 21, 2013 | SESE |
| [DEN130013](/device/DEN130013.md) | VITEK MS | bioMerieux, Inc. | Aug 21, 2013 | DENG |

## Top Applicants

- Bruker Daltonics, Inc. — 2 clearances
- bioMerieux, Inc. — 2 clearances
- Bruker Daltonik GmbH — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/PEX](https://fda.innolitics.com/productcode/PEX)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
