Browse hierarchy: [Orthopedic (OR)](/submissions/OR) → [Subpart D — Prosthetic Devices](/submissions/OR/subpart-d%E2%80%94prosthetic-devices) → [21 CFR 888.3030](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/888.3030) → OSN — Software For Diagnosis/Treatment

# OSN · Software For Diagnosis/Treatment

_Orthopedic · 21 CFR 888.3030 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/OSN

## Overview

- **Product Code:** OSN
- **Device Name:** Software For Diagnosis/Treatment
- **Regulation:** [21 CFR 888.3030](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/888.3030)
- **Device Class:** 2
- **Review Panel:** [Orthopedic](/submissions/OR)
- **Implant:** yes

## Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Classification Rationale

Class II.

## Recent Cleared Devices (4 of 4)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K253764](/device/K253764.md) | ENOS Software Guided External Fixation System | Disior, Ltd. | Feb 26, 2026 | SESE |
| [K221792](/device/K221792.md) | Acute QC Strut and Components | Smith & Nephew, Inc. | Aug 25, 2022 | SESE |
| [K180539](/device/K180539.md) | Deformity Analysis and Correction Software (DACS) and Instrumentation | Arrowhead Medical Device Technologies, LLC | Aug 13, 2018 | SESE |
| [K140550](/device/K140550.md) | ORTHOHUB EXTERNAL FIXATOR SOFTWARE | Orthohub, Inc. | Aug 25, 2014 | SESE |

## Top Applicants

- Arrowhead Medical Device Technologies, LLC — 1 clearance
- Disior, Ltd. — 1 clearance
- Orthohub, Inc. — 1 clearance
- Smith & Nephew, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/OSN](https://fda.innolitics.com/productcode/OSN)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com