Browse hierarchy: [Immunology (IM)](/submissions/IM) → [Subpart G — Tumor Associated Antigen Immunological Test Systems](/submissions/IM/subpart-g%E2%80%94tumor-associated-antigen-immunological-test-systems) → [21 CFR 866.6030](/submissions/IM/subpart-g%E2%80%94tumor-associated-antigen-immunological-test-systems/866.6030) → OAU — Des-Gamma-Carboxy-Prothrombin (Dcp), Risk Assessment, Hepatocellular Carcinoma

# OAU · Des-Gamma-Carboxy-Prothrombin (Dcp), Risk Assessment, Hepatocellular Carcinoma

_Immunology · 21 CFR 866.6030 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/OAU

## Overview

- **Product Code:** OAU
- **Device Name:** Des-Gamma-Carboxy-Prothrombin (Dcp), Risk Assessment, Hepatocellular Carcinoma
- **Regulation:** [21 CFR 866.6030](/submissions/IM/subpart-g%E2%80%94tumor-associated-antigen-immunological-test-systems/866.6030)
- **Device Class:** 2
- **Review Panel:** [Immunology](/submissions/IM)
- **3rd-party reviewable:** yes

## Identification

An AFP-L3% immunological test system is an in vitro device that consists of reagents and an automated instrument used to quantitatively measure, by immunochemical techniques, AFP and AFP-L3 subfraction in human serum. The device is intended for in vitro diagnostic use as an aid in the risk assessment of patients with chronic liver disease for development of hepatocellular carcinoma, in conjunction with other laboratory findings, imaging studies, and clinical assessment.

## Classification Rationale

Class II (special controls). The special control is FDA's guidance document entitled “Class II Special Controls Guidance Document: AFP-L3% Immunological Test Systems.” See § 866.1(e) for the availability of this guidance document.

## Special Controls

*Classification.* Class II (special controls). The special control is FDA's guidance document entitled “Class II Special Controls Guidance Document: AFP-L3% Immunological Test Systems.” See § 866.1(e) for the availability of this guidance document.

## Recent Cleared Devices (1 of 1)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K062368](/device/K062368.md) | WAKO LBA DCP TEST SYSTEM, MODEL 993-05301; DCP CONTROL SET, MODEL 995-0551; DCP CALIBRATOR SET, LIBASYS, MODEL 999-05401 | Wako Chemicals USA, Inc. | Jan 31, 2007 | SESE |

## Top Applicants

- Wako Chemicals USA, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/OAU](https://fda.innolitics.com/productcode/OAU)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com