NJD · Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer

Orthopedic · 21 CFR 888.3535 · Class 2

Overview

Product CodeNJD
Device NameProsthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
Regulation21 CFR 888.3535
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surface. It has no linkage across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra-high molecular weight polyethylene tibial bearing is rigidly secured to the metal tibial baseplate.

Classification Rationale

Class II (special controls). The special control is FDA's guidance: “Class II Special Controls Guidance Document: Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses; Guidance for Industry and FDA.” See § 888.1 for the availability of this guidance.

Special Controls

*Classification.* Class II (special controls). The special control is FDA's guidance: “Class II Special Controls Guidance Document: Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses; Guidance for Industry and FDA.” See § 888.1 for the availability of this guidance.

Recent Cleared Devices (5 of 5)

RecordDevice NameApplicantDecision DateDecision
K251975Achieve Partial Knee System - Porous Coated CoCrMo Femoral ComponentIgnite OrthomotionSep 2, 2025SESE
K242307ACHIEVE Partial Knee SystemIgnite OrthomotionDec 16, 2024SESE
K222653JOURNEY II UK™ and ENGAGE™ Cementless Partial Knee SystemSmith+Nephew, Inc.Oct 28, 2022SESE
K190439Engage™ Partial Knee SystemEngage Uni, LLCNov 21, 2019SESE
K133811RESTORIS POROUS PARTIAL KNEE SYSTEMMako Surgical Corp.Jul 8, 2014SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...