NAM · Stimulator, Peripheral Nerve, Non-Implanted, For Urinary Incontinence

Gastroenterology, Urology · 21 CFR 876.5310 · Class 2

Overview

Product CodeNAM
Device NameStimulator, Peripheral Nerve, Non-Implanted, For Urinary Incontinence
Regulation21 CFR 876.5310
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

A nonimplanted, peripheral electrical continence device is a device that consists of an electrode that is connected by an electrical cable to a battery-powered pulse source. The electrode is placed onto or inserted into the body at a peripheral location and used to stimulate the nerves associated with pelvic floor function to maintain urinary continence. When necessary, the electrode may be removed by the user.

Classification Rationale

Class II, subject to the following special controls:

Special Controls

*Classification.* Class II, subject to the following special controls:(1) That sale, distribution, and use of this device are restricted to prescription use in accordance with § 801.109 of this chapter. (2) That the labeling must bear all information required for the safe and effective use of the device as outlined in § 801.109(c) of this chapter, including a detailed summary of the clinical information upon which the instructions are based.

In addition to the general controls of the act, the Percutaneous SANS Device is subject to the following special controls: (1) The sale, distribution and use of this device are restricted to prescription use in accordance with 21 CFR 801.109. (2) Clinical data are necessary. (3) The labeling must include (a) warnings indicating the need to evaluate the patient during treatment for pain or skin irritation/inflammation; (b) precautions indicating the need to read and understand all directions before using this device; (c) specific instructions to describe proper patients set-up prior to the start of treatment, including proper placement of the electrodes; (d) stimulation parameters and duration and frequency of treatments in accordance with the protocol used during clinical trial; and (e) a summary of the clinical data collected including a listing of adverse events reported.

Recent Cleared Devices (8 of 8)

RecordDevice NameApplicantDecision DateDecision
K220454Vivally System Wearable, Non-Invasive Neuromodulation System and Mobile ApplicationAvation Medical, Inc.Apr 3, 2023SESE
K192731ZIDA Wearable Neuromodulation SystemExodus InnovationsMar 19, 2021SESE
K132561NURO NEUROMODULATION SYSTEMAdvanced Uro-Solutions, Inc.Nov 5, 2013SESE
K101847URGENT PC STIMULATOR; URGENT PC LEAD SETUroplasty, Inc.Oct 21, 2010SESE
K071822URGENT PC NEUROMODULATION SYSTEM, MODELS UPC200 AND UPC250-12Uroplasty, Inc.Aug 20, 2007SESE
K061333URGENT PC NEUROMODULATION SYSTEM, MODELS UPC200-A AND UPC250-12Uroplasty, Inc.Jul 3, 2006SESE
K052025URGENT PC NEUROMODULATION SYSTEMUroplasty, Inc.Oct 17, 2005SESE
DEN000002UROSURGE PERCUTANEOUS SANS (STOLLER AFFERENT NERVE STIMULATOR) DEVICEUrosurge, Inc.Feb 9, 2000DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...