Browse hierarchy: [Radiology (RA)](/submissions/RA) → [Subpart B — Diagnostic Devices](/submissions/RA/subpart-b%E2%80%94diagnostic-devices) → [21 CFR 892.2070](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/892.2070) → MYN — Analyzer, Medical Image

# MYN · Analyzer, Medical Image

_Radiology · 21 CFR 892.2070 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/MYN

## Overview

- **Product Code:** MYN
- **Device Name:** Analyzer, Medical Image
- **Regulation:** [21 CFR 892.2070](/submissions/RA/subpart-b%E2%80%94diagnostic-devices/892.2070)
- **Device Class:** 2
- **Review Panel:** [Radiology](/submissions/RA)

## Identification

Medical image analyzers, including computer-assisted/aided detection (CADe) devices for mammography breast cancer, ultrasound breast lesions, radiograph lung nodules, and radiograph dental caries detection, is a prescription device that is intended to identify, mark, highlight, or in any other manner direct the clinicians' attention to portions of a radiology image that may reveal abnormalities during interpretation of patient radiology images by the clinicians. This device incorporates pattern recognition and data analysis capabilities and operates on previously acquired medical images. This device is not intended to replace the review by a qualified radiologist, and is not intended to be used for triage, or to recommend diagnosis.

## Classification Rationale

Class II (special controls). The special controls for this device are:

## Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) Design verification and validation must include:
(i) A detailed description of the image analysis algorithms including a description of the algorithm inputs and outputs, each major component or block, and algorithm limitations.
(ii) A detailed description of pre-specified performance testing methods and dataset(s) used to assess whether the device will improve reader performance as intended and to characterize the standalone device performance. Performance testing includes one or more standalone tests, side-by-side comparisons, or a reader study, as applicable.
(iii) Results from performance testing that demonstrate that the device improves reader performance in the intended use population when used in accordance with the instructions for use. The performance assessment must be based on appropriate diagnostic accuracy measures (
*e.g.,* receiver operator characteristic plot, sensitivity, specificity, predictive value, and diagnostic likelihood ratio). The test dataset must contain a sufficient number of cases from important cohorts (*e.g.,* subsets defined by clinically relevant confounders, effect modifiers, concomitant diseases, and subsets defined by image acquisition characteristics) such that the performance estimates and confidence intervals of the device for these individual subsets can be characterized for the intended use population and imaging equipment.(iv) Appropriate software documentation (
*e.g.,* device hazard analysis; software requirements specification document; software design specification document; traceability analysis; description of verification and validation activities including system level test protocol, pass/fail criteria, and results; and cybersecurity).(2) Labeling must include the following:
(i) A detailed description of the patient population for which the device is indicated for use.
(ii) A detailed description of the intended reading protocol.
(iii) A detailed description of the intended user and user training that addresses appropriate reading protocols for the device.
(iv) A detailed description of the device inputs and outputs.
(v) A detailed description of compatible imaging hardware and imaging protocols.
(vi) Discussion of warnings, precautions, and limitations must include situations in which the device may fail or may not operate at its expected performance level (
*e.g.,* poor image quality or for certain subpopulations), as applicable.(vii) Device operating instructions.
(viii) A detailed summary of the performance testing, including: test methods, dataset characteristics, results, and a summary of sub-analyses on case distributions stratified by relevant confounders, such as lesion and organ characteristics, disease stages, and imaging equipment.

## Recent Cleared Devices (20 of 48)

Showing 20 most recent of 48 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K252953](/device/K252953.md) | Velmeni for Dentists (V4D)  Endo-Perio | Velmeni, Inc. | May 11, 2026 | SESE |
| [K251934](/device/K251934.md) | qXR-Detect | Qure.Ai Technologies | Jan 16, 2026 | SESE |
| [K252934](/device/K252934.md) | Diagnocat | DGNCT, LLC | Jan 15, 2026 | SESE |
| [K253009](/device/K253009.md) | DS Core Detect | Dentsply Sirona, Inc. | Jan 7, 2026 | SESE |
| [K252086](/device/K252086.md) | DTX Studio Assist | Nobel Biocare C/O Medicim NV | Nov 17, 2025 | SESE |
| [K250525](/device/K250525.md) | Second Opinion® Panoramic | Pearl, Inc. | Nov 14, 2025 | SESE |
| [K250264](/device/K250264.md) | SugarBug (1.x) | Bench7, Inc. | Nov 7, 2025 | SESE |
| [K251002](/device/K251002.md) | Videa Dental AI | Videahealth, Inc. | Sep 19, 2025 | SESE |
| [K250753](/device/K250753.md) | VELMENI for DENTISTS (V4D) | Velmeni, Inc. | Sep 2, 2025 | SESE |
| [K243234](/device/K243234.md) | Second Opinion® CS | Pearl, Inc. | Jun 12, 2025 | SESE |
| [K242437](/device/K242437.md) | Smile Dx® | Cube Click, Inc. | May 14, 2025 | SESE |
| [K243893](/device/K243893.md) | Second Opinion® Pediatric | Pearl, Inc. | May 5, 2025 | SESE |
| [K243239](/device/K243239.md) | Lung AI (LAI001) | Exo, Inc. | Apr 24, 2025 | SESE |
| [K242600](/device/K242600.md) | Second Opinion Periapical Radiolucency Contours | Pearl, Inc. | Apr 11, 2025 | SESE |
| [K243831](/device/K243831.md) | Rayvolve LN | AZmed | Mar 26, 2025 | SESE |
| [K241725](/device/K241725.md) | Better Diagnostics Caries Assist (BDCA) Version 1.0 | Better Diagnostics AI Corp. | Mar 11, 2025 | SESE |
| [K241620](/device/K241620.md) | ChestView US | Gleamer Sas | Feb 27, 2025 | SESE |
| [K242522](/device/K242522.md) | Second Opinion CC | Pearl, Inc. | Jan 16, 2025 | SESE |
| [K240003](/device/K240003.md) | Velmeni for Dentists (V4D) | Velmeni, Inc. | Aug 30, 2024 | SESE |
| [K233738](/device/K233738.md) | Overjet Caries Assist-Pediatric | Overjet, Inc. | Mar 4, 2024 | SESE |

## Top Applicants

- Pearl, Inc. — 6 clearances
- Overjet, Inc. — 5 clearances
- Icad, Inc. — 4 clearances
- Imagen Technologies, Inc. — 4 clearances
- Velmeni, Inc. — 3 clearances

---

**Source:** [https://fda.innolitics.com/productcode/MYN](https://fda.innolitics.com/productcode/MYN)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com