# MYE · System, Electrogastrography (Egg)

_Gastroenterology, Urology · 21 CFR 876.1735 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/MYE

## Overview

- **Product Code:** MYE
- **Device Name:** System, Electrogastrography (Egg)
- **Regulation:** [21 CFR 876.1735](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1735)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)

## Identification

An electrogastrography system (EGG) is a device used to measure gastric myoelectrical activity as an aid in the diagnosis of gastric motility disorders. The device system includes the external recorder, amplifier, skin electrodes, strip chart, cables, analytical software, and other accessories.

## Classification Rationale

Class II (Special Controls). The special controls are as follows:

## Special Controls

*Classification.* Class II (Special Controls). The special controls are as follows:(1) The sale, distribution and use of this device are restricted to prescription use in accordance with § 801.109 of this chapter.
(2) The labeling must include specific instructions:
(i) To describe proper patient set-up prior to the start of the test, including the proper placement of electrodes;
(ii) To describe how background data should be gathered and used to eliminate artifact in the data signal;
(iii) To describe the test protocol (including the measurement of baseline data) that may be followed to obtain the EGG signal; and
(iv) To explain how data results may be interpreted.
(3) The device design should ensure that the EGG signal is distinguishable from background noise that may interfere with the true gastric myoelectric signal.
(4) Data should be collected to demonstrate that the device has adequate precision and the EGG signal is reproducible and is interpretable.

In addition to the general controls of the act, the 3CPM EGG Machine is subject to the following special controls: (1) The sale, distribution and use of this device are restricted to prescription use in accordance with 21 CFR 801.109. (2) The labeling must include specific instructions (a) to describe proper patient set-up prior to the start of the test, including the proper placement of electrodes; (b) to describe how background data should be gathered and used to eliminate artifact in the data signal; (c) to describe the test protocol (including the measurement of baseline data) which may be followed to obtain the EGG signal; and (d) to explain how data results may be interpreted. (3) The device design should ensure that the EGG signal is distinguishable from background noise that may interfere with the true gastric myoelectric signal. (4) Data should be collected to demonstrate that the device has adequate precision and the EGG signal is reproducible and is interpretable.

## Recent Cleared Devices (8 of 8)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K252504](/device/K252504.md) | Gastric Alimetry | Alimetry , Ltd. | Dec 5, 2025 | SESE |
| [K240946](/device/K240946.md) | Gastric Alimetry | Alimetry , Ltd. | Jul 3, 2024 | SESE |
| [K232925](/device/K232925.md) | Gastric Alimetry System | Alimetry , Ltd. | Nov 17, 2023 | SESE |
| [K223398](/device/K223398.md) | Gastric Alimetry System | Alimetry , Ltd. | Apr 27, 2023 | SESE |
| [K213924](/device/K213924.md) | Gastric Alimetry System | Alimetry , Ltd. | Jun 3, 2022 | SESE |
| [K212954](/device/K212954.md) | G-Tech Wireless Patch System (WPS) | G-Tech Medical | Jan 10, 2022 | SESE |
| [K014269](/device/K014269.md) | POLYGRAM NET ELECTROGASTROGRAPHY APPLICATION SOFTWARE, MODEL 9043S0151; POLYGRAF ID, MODEL 9043G0102 | Medtronic Functional Diagnostics A/S | Nov 21, 2002 | SESE |
| [DEN990005](/device/DEN990005.md) | THE 3PM EGG MACHINE | 3pm Co., Inc. | Aug 20, 1999 | DENG |

## Top Applicants

- Alimetry , Ltd. — 5 clearances
- 3pm Co., Inc. — 1 clearance
- G-Tech Medical — 1 clearance
- Medtronic Functional Diagnostics A/S — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/MYE](https://fda.innolitics.com/productcode/MYE)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).