MNI · Orthosis, Spinal Pedicle Fixation

Orthopedic · 21 CFR 888.3070 · Class 2

Overview

Product CodeMNI
Device NameOrthosis, Spinal Pedicle Fixation
Regulation21 CFR 888.3070
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

(1) Rigid pedicle screw systems are comprised of multiple components, made from a variety of materials that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of screws, longitudinal members (e.g., plates, rods including dual diameter rods, plate/rod combinations), transverse or cross connectors, and interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors).(2) Semi-rigid systems are defined as systems that contain one or more of the following features (including but not limited to): Non-uniform longitudinal elements, or features that allow more motion or flexibility compared to rigid systems.

Classification Rationale

Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls. (Also includes Class II designations for rigid systems for degenerative disc disease and semi-rigid systems).

Special Controls

*Classification.* (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:(i) Compliance with material standards; (ii) Compliance with mechanical testing standards; (iii) Compliance with biocompatibility standards; and (iv) Labeling that contains these two statements in addition to other appropriate labeling information: “Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.” “Precaution: The implantation of pedicle screw spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this pedicle screw spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.” (2) Class II (special controls), when a rigid pedicle screw system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion in the treatment of degenerative disc disease and spondylolisthesis other than either severe spondylolisthesis (grades 3 and 4) at L5-S1 or degenerative spondylolisthesis with objective evidence of neurologic impairment. These pedicle screw systems must comply with the following special controls: (i) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (ii) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant. (iii) Device components must be demonstrated to be biocompatible. (iv) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (v) Labeling must include the following: (A) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (B) Intended use and indications for use, including levels of fixation; (C) Identification of magnetic resonance (MR) compatibility status; (D) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user; and (E) Detailed instructions of each surgical step, including device removal. (3) Class II (special controls), when a semi-rigid system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion for any indication. In addition to complying with the special controls in paragraphs (b)(2)(i) through (v) of this section, these pedicle screw systems must comply with the following special controls: (i) Demonstration that clinical performance characteristics of the device support the intended use of the product, including assessment of fusion compared to a clinically acceptable fusion rate. (ii) Semi-rigid systems marketed prior to the effective date of this reclassification must submit an amendment to their previously cleared premarket notification (510(k)) demonstrating compliance with the special controls in paragraphs (b)(2)(i) through (v) and paragraph (b)(3)(i) of this section.

Recent Cleared Devices (20 of 303)

Showing 20 most recent of 303 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K171497Mikron Spinal Fixation SystemMikron Makina Sanayi Ticaret Co. , Ltd.Oct 12, 2017SESE
K160731LumFix Spinal Fixation SytemCG Bio Co., Ltd.Oct 4, 2016SESE
K151458Double Medical Universal Spine SystemDouble Medical Technology, Inc.Aug 22, 2016SESE
K153273MySpine Pedicle Screw Placement Guides - LPMedacta International S.A.Jun 29, 2016SESE
K160124LUMIS Cannulated Pedicle Screw Fixation System, U.L.I.S. Pedicle Screw Fixation SystemSpinevision S.A.Apr 4, 2016SESE
K160320PremierShandong Weigao Orthopaedic Device Co., Ltd.Apr 1, 2016SESE
K160003Sniper (R) Spine SystemSpine Wave, Inc.Feb 26, 2016SESE
K152324YAHUA Spinal SystemBeijing Weigao Yahua Artificial Joint Development Co. , Ltd.Feb 1, 2016SESE
K143222FIREFLY Pedicle Screw Navigation GuideMighty Oak Medical, Inc.Dec 11, 2015SESE
K150684WASTON General Spinal SystemChangzhou Waston Medical Appliance Co., Ltd.Nov 18, 2015SESE
K152132X-spine Pedicle Screw SystemX-Spine Systems, Inc.Sep 25, 2015SESE
K151592Gemmed pedicle screw spinal systemSuzhou Gemmed Medical Instrument Co., Ltd.Sep 24, 2015SESE
K152131Reliance Spinal Screw SystemReliance Medical Systems, LLCSep 17, 2015SESE
K152098ODALYS Pedicle Screw SystemKisco InternationalSep 17, 2015SESE
K152174Sniper Spine SystemSpine Wave, Inc.Aug 31, 2015SESE
K151813Sniper Spine SystemSpine Wave, Inc.Jul 31, 2015SESE
K150294DPZ Pedicular Fixation SystemOsteomed Implantes, LtdaJun 5, 2015SESE
K150647Polyscrew Pedicle Screw SystemNew Era Orthopedics, LLCApr 8, 2015SESE
K150049PASS LP Spinal SystemMedicrea InternationalFeb 10, 2015SESE
K141253NEW ERA ORTHOPAEDICS POLYSCREW PEDICLE SCREW SYSTEMNew Era Orthopaedics, LLCJan 9, 2015SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...