MAX · Intervertebral Fusion Device With Bone Graft, Lumbar

Orthopedic · 21 CFR 888.3080 · Class 2

Overview

Product CodeMAX
Device NameIntervertebral Fusion Device With Bone Graft, Lumbar
Regulation21 CFR 888.3080
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

An intervertebral body fusion device is an implanted single or multiple component spinal device made from a variety of materials, including titanium and polymers. The device is inserted into the intervertebral body space of the cervical or lumbosacral spine, and is intended for intervertebral body fusion.

Classification Rationale

(1) Class II (special controls) for intervertebral body fusion devices that contain bone grafting material. The special control is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intervertebral Body Fusion Device.” See § 888.1(e) for the availability of this guidance document.(2) Class III (premarket approval) for intervertebral body fusion devices that include any therapeutic biologic (e.g., bone morphogenic protein). Intervertebral body fusion devices that contain any therapeutic biologic require premarket approval.

Special Controls

*Classification.* (1) Class II (special controls) for intervertebral body fusion devices that contain bone grafting material. The special control is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intervertebral Body Fusion Device.” See § 888.1(e) for the availability of this guidance document.(2) Class III (premarket approval) for intervertebral body fusion devices that include any therapeutic biologic (e.g., bone morphogenic protein). Intervertebral body fusion devices that contain any therapeutic biologic require premarket approval. (c) *Date premarket approval application (PMA) or notice of product development protocol (PDP) is required.* Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.

Recent Cleared Devices (20 of 903)

Showing 20 most recent of 903 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K261049SCALA® TLSpineart SAAug 20, 2026SESE
K261430TruLift Expandable SystemLife Spine, Inc.Jul 28, 2026SESE
K253011Catalyft PL Expandable Interbody SystemMedtronic Sofamor Danek USA, Inc.Jul 17, 2026SESE
K261020Symmetrix™ L Spinal SystemMedtronic Sofamor Danek USA, Inc.Jul 14, 2026SESE
K253420Admiral ACP System; Explorer TO System; Laminoplasty System; Manta Ray TDF Spacer; Meridian Interbody System; Meridian Anterior Plate System; Reef L Interbody System; Reef TO/TA System; Regatta Lateral System; Regatta Lateral Plate System; Shoreline ACS Interbody System; Shoreline Threaded TruProfile Plate; Shoreline RT Interbody System; Vu Mesh; WaveForm A Interbody System; WaveForm C Interbody System; WaveForm L Interbody System; WaveForm TA Interbody System; WaveForm TO Interbody SySeaSpine Orthopedics CorporationJul 1, 2026SESE
K253151Fule Interbody Fusion Cage SystemBeijing Fule Science & Technology Development Co., Ltd.Jun 15, 2026SESE
K261159Exceed® Biplanar Expandable Interbody SystemSpine Wave, Inc.May 29, 2026SESE
K253894BMD Titanium Spinal Fusion SystemGlobal Biomedica s.r.o.May 28, 2026SESE
K260506Ventana® P/T Lumbar Interbody SystemSpinal Elements, Inc.May 15, 2026SESE
K260837VersaLift Expandable SystemLife Spine, Inc.May 12, 2026SESE
K260385aprevo® anterior and lateral lumbar interbody system; aprevo® posterior and transforaminal lumbar interbody system; aprevo® cervical interbody system; corra™ cervical plating systemCarlsmed, Inc.May 9, 2026SESE
K261067BEE PLIF CageNGMedical GmbHApr 30, 2026SESE
K254017SWINGO-3D Lumbar Cage SystemImplanetFeb 26, 2026SESE
K253583LUX Expandable Lumbar Interbody SystemXenix MedicalFeb 23, 2026SESE
K250773Luna® Ti Interbody Fusion SystemSpinal Elements, Inc.Feb 4, 2026SESE
K253748Life Spine ProLift & ProLift Lateral and ProLift Lateral Fixated Expandable Spacer SystemLife Spine, Inc.Jan 23, 2026SESE
K253266Titanium Interbody SystemSpine Innovation, LLCJan 8, 2026SESE
K253577IB3D™ PL Spinal System (A24000000 / IB3D Universal Implant Inserter)Medicrea International S.A.S. (Medtronic)Dec 19, 2025SESE
K252610ZSFab Lumbar Interbody SystemZsfab, Inc.Nov 25, 2025SESE
K252351UniSpace® TPLIF CageCg Medtech Co., Ltd.Oct 28, 2025SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...