Browse hierarchy: [Clinical Toxicology (TX)](/submissions/TX) → [Subpart D — Clinical Toxicology Test Systems](/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems) → [21 CFR 862.3170](/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/862.3170) → LAA — High Pressure Liquid Chromatography, Benzodiazepine

# LAA · High Pressure Liquid Chromatography, Benzodiazepine

_Clinical Toxicology · 21 CFR 862.3170 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/LAA

## Overview

- **Product Code:** LAA
- **Device Name:** High Pressure Liquid Chromatography, Benzodiazepine
- **Regulation:** [21 CFR 862.3170](/submissions/TX/subpart-d%E2%80%94clinical-toxicology-test-systems/862.3170)
- **Device Class:** 2
- **Review Panel:** [Clinical Toxicology](/submissions/TX)
- **3rd-party reviewable:** yes

## Identification

A benzodiazepine test system is a device intended to measure any of the benzodiazepine compounds, sedative and hypnotic drugs, in blood, plasma, and urine. The benzodiazepine compounds include chlordiazepoxide, diazepam, oxazepam, chlorzepate, flurazepam, and nitrazepam. Measurements obtained by this device are used in the diagnosis and treatment of benzodiazepine use or overdose and in monitoring levels of benzodiazepines to ensure appropriate therapy.

## Classification Rationale

Class II (special controls). A benzodiazepine test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (e.g., programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

## Special Controls

*Classification.* Class II (special controls). A benzodiazepine test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (*e.g.,* programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

## Recent Cleared Devices (1 of 1)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K955116](/device/K955116.md) | BENZODIAZEPINES BY REMEDI HS | Bio-Rad | Jan 30, 1996 | SESE |

## Top Applicants

- Bio-Rad — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/LAA](https://fda.innolitics.com/productcode/LAA)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
