KXE · Prosthesis, Wrist, Hemi-, Ulnar

Orthopedic · 21 CFR 888.3810 · Class 2

Overview

Product CodeKXE
Device NameProsthesis, Wrist, Hemi-, Ulnar
Regulation21 CFR 888.3810
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A wrist joint ulnar (hemi-wrist) polymer prosthesis is a mushroom-shaped device made of a medical grade silicone elastomer or ultra-high molecular weight polyethylene intended to be implanted into the intramedullary canal of the bone and held in place by a suture. Its purpose is to cover the resected end of the distal ulna to control bone overgrowth and to provide an articular surface for the radius and carpus.

Classification Rationale

Class II.

Recent Cleared Devices (16 of 16)

RecordDevice NameApplicantDecision DateDecision
K190599Aptis Medical Distal Radio Ulnar Joint ImplantAptis Medical, LLCMay 3, 2019SESE
K142569Aptis Medical Distal Radio Ulnar Joint ImplantAptis Medical, LLCApr 3, 2015SESE
K112481FIRST CHOICE DRUJ SYSTEM, PARTIAL HEAD IMPLANTAscension OrthopedicApr 9, 2012SESE
K081025ISOELASTICURemi Sciences, Inc.Nov 21, 2008SESE
K082839DISTAL RADIO-ULNAR JOINT IMPLANTAptis Medical, LLCOct 24, 2008SESE
K061146SBI ULNAR HEAD IMPLANTSmall Bone Innovations, Inc.Jul 19, 2006SESE
K053119DISTAL RADIO-ULNAR JOINT IMPLANTAptis Medical, LLCDec 7, 2005SESE
K052137ASCENSION MUHAscension Orthopedics, Inc.Nov 3, 2005SESE
K040497DISTAL RADIO-ULNAR JOINT IMPLANTAptis Medical, LLCJan 26, 2005SESE
K042902HERBERT ULNAR HEAD PROSTHESIS SYSTEMStuckenbrock Medizintechnik GmbHDec 27, 2004SESE
K033930KAPP CUSTOM ULNAR HEAD WRIST IMPLANTKapp Surgical Instrument, Inc.Jul 28, 2004SESE
K020274WMT MODULAR ULNAR HEAD IMPLANTWrightmedicaltechnologyincFeb 22, 2002SESE
K010786ULNAR HEAD IMPLANTAvanta Orthopaedics, Inc.Apr 11, 2001SESE
K982268ULNAR HEAD IMPLANTAvanta Orthopaedics, Inc.Dec 4, 1998SESE
K812053SILASTIC HEMI WRIST IMPLANT H.P. (RAD.)Dow Corning Corp. Healthcare Industries MaterialsAug 18, 1981SESE
K790125ULNAR HEAD PROTHESISCutter Laboratories, Inc.Feb 8, 1979SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...