Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5630](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5630) → KPF — System, Dialysate Delivery, Semi-Automatic, Peritoneal

# KPF · System, Dialysate Delivery, Semi-Automatic, Peritoneal

_Gastroenterology, Urology · 21 CFR 876.5630 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/KPF

## Overview

- **Product Code:** KPF
- **Device Name:** System, Dialysate Delivery, Semi-Automatic, Peritoneal
- **Regulation:** [21 CFR 876.5630](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5630)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **Life-sustaining:** yes

## Identification

(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.

## Classification Rationale

Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

## Special Controls

*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

## Recent Cleared Devices (13 of 13)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K061515](/device/K061515.md) | RENALSOFT | Baxter Healthcare Corp | Sep 11, 2006 | SESE |
| [K990953](/device/K990953.md) | RENAL LINK | Baxter Healthcare Corp | Jun 18, 1999 | SESE |
| [K970989](/device/K970989.md) | CYBERREN | Cybernius Medical , Ltd. | Jul 24, 1997 | SESE |
| [K955762](/device/K955762.md) | PACKPD PERITONEAL DIALYSIS UREA KINETIC MODELING SOFTWARE PROGRAM | Fresenius USA, Inc. | Jul 31, 1996 | SESE |
| [K913515](/device/K913515.md) | TOTAL CONTAINMENT DEVICE | Denco | May 26, 1994 | SESE |
| [K875121](/device/K875121.md) | AMICON EQUALINE FLUID BALANCE SYSTEM | Amicon, Inc. | Feb 19, 1988 | SESE |
| [K874020](/device/K874020.md) | ULTRACARE(TM) AUTOMATED PATIENT ASSIST DEVICE | Abbott Laboratories | Jan 29, 1988 | SESE |
| [K821328](/device/K821328.md) | C.A.P.D. AUTOMATIC HEATER #PDC 2000 HCP | Medionics International , Ltd. | Jul 28, 1982 | SESE |
| [K802831](/device/K802831.md) | GAMBRO PERITONEAL DIALYSIS MONITOR | Gambro, Inc. | Dec 18, 1980 | SESE |
| [K800496](/device/K800496.md) | CYCLER W/5 OR 10 HR. FILL/DWELL TIMER | American Medical Products, Inc. | Jul 21, 1980 | SESE |
| [K791676](/device/K791676.md) | PERITONEAL DIALYSIS CYCLER MODEL PDC1000 | J.M. Sounds Electronics Co. | Dec 6, 1979 | SESE |
| [K791584](/device/K791584.md) | CYLER/HEATER FOR PERITONEAL DIALYSIS | American Medical Products, Inc. | Nov 16, 1979 | SESE |
| [K790091](/device/K790091.md) | AMP AUTOMATIC CYCLER STAND | American Medical Products, Inc. | Feb 16, 1979 | SESE |

## Top Applicants

- American Medical Products, Inc. — 3 clearances
- Baxter Healthcare Corp — 2 clearances
- Abbott Laboratories — 1 clearance
- Amicon, Inc. — 1 clearance
- Cybernius Medical , Ltd. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/KPF](https://fda.innolitics.com/productcode/KPF)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com