JZH · Factor B, Antigen, Antiserum, Control

Immunology · 21 CFR 866.5320 · Class 2

Overview

Product CodeJZH
Device NameFactor B, Antigen, Antiserum, Control
Regulation21 CFR 866.5320
Device ClassClass 2
Review PanelImmunology

Identification

A properdin factor B immunological test system is a device that consists of the reagents used to measure by immunochemical techniques properdin factor B in serum and other body fluids. The deposition of properdin factor B in body tissues or a corresponding depression in the amount of properdin factor B in serum and other body fluids is evidence of the involvement of the alternative to the classical pathway of activation of complement (a group of plasma proteins which cause the destruction of cells which are foreign to the body). Measurement of properdin factor B aids in the diagnosis of several kidney diseases, e.g., chronic glomerulonephritis (inflammation of the glomeruli of the kidney), lupus nephritis (kidney disease associated with a multisystem autoimmune disease, systemic lupus erythematosus), as well as several skin diseases, e.g., dermititis herpetiformis (presence of vesicles on the skin that burn and itch), and pemphigus vulgaris (large vesicles on the skin). Other diseases in which the alternate pathway of complement activation has been implicated include rheumatoid arthritis, sickle cell anemia, and gram-negative bacteremia.

Classification Rationale

Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

Recent Cleared Devices (6 of 6)

RecordDevice NameApplicantDecision DateDecision
K964843IMMAGE IMMUNOCHEMISTRY SYSTEM PROPERDIN FACTOR B (PFB) REAGENTBeckman Instruments, Inc.Mar 6, 1997SESE
K882623PROPERDIN FACTOR B FOR TECHNICON DPA-1(TM) SYSTEMTechnicon Instruments Corp.Jul 8, 1988SESE
K831959RADIAL IMMUNO-TEST FOR HUMAN FACTOR BKent Laboratories, Inc.Jul 19, 1983SESE
K811740KALLESTAD'S ENDOPLATE FACTOR B TESTKallestad Laboratories, Inc.Jul 16, 1981SESE
K781016C3PA (GBG) PROPERDIN FACTOR BIcl ScientificAug 14, 1978SESE
K772084LAS-R HUMAN C3 PROACTIVATOR TESTHyland Therapeutic Div., Travenol LaboratoriesJan 24, 1978SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...