Browse hierarchy: [Hematology (HE)](/submissions/HE) → [Subpart G — Manual Hematology Devices](/submissions/HE/subpart-g%E2%80%94manual-hematology-devices) → [21 CFR 864.6550](/submissions/HE/subpart-g%E2%80%94manual-hematology-devices/864.6550) → JIP — Blood, Occult, Enzymatic Method, In Urine

# JIP · Blood, Occult, Enzymatic Method, In Urine

_Hematology · 21 CFR 864.6550 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/JIP

## Overview

- **Product Code:** JIP
- **Device Name:** Blood, Occult, Enzymatic Method, In Urine
- **Regulation:** [21 CFR 864.6550](/submissions/HE/subpart-g%E2%80%94manual-hematology-devices/864.6550)
- **Device Class:** 2
- **Review Panel:** [Hematology](/submissions/HE)
- **3rd-party reviewable:** yes

## Identification

An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is blood present in such small quantities that it can be detected only by chemical tests of suspected material, or by microscopic or spectroscopic examination.)

## Classification Rationale

Class II (special controls). A control intended for use with an occult blood test is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

## Special Controls

*Classification.* Class II (special controls). A control intended for use with an occult blood test is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

## Recent Cleared Devices (0 of 0)

_No cleared devices on record._

---

**Source:** [https://fda.innolitics.com/productcode/JIP](https://fda.innolitics.com/productcode/JIP)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
