Browse hierarchy: [Orthopedic (OR)](/submissions/OR) → [Subpart D — Prosthetic Devices](/submissions/OR/subpart-d%E2%80%94prosthetic-devices) → [21 CFR 888.3150](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/888.3150) → JDC — Prosthesis, Elbow, Constrained, Cemented

# JDC · Prosthesis, Elbow, Constrained, Cemented

_Orthopedic · 21 CFR 888.3150 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/JDC

## Overview

- **Product Code:** JDC
- **Device Name:** Prosthesis, Elbow, Constrained, Cemented
- **Regulation:** [21 CFR 888.3150](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/888.3150)
- **Device Class:** 2
- **Review Panel:** [Orthopedic](/submissions/OR)
- **Implant:** yes

## Identification

An elbow joint metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace an elbow joint. It is made of alloys, such as cobalt-chromium-molybdenum, or of these alloys and of an ultra-high molecular weight polyethylene bushing. The device prevents dislocation in more than one anatomic plane and consists of two components that are linked together. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).

## Classification Rationale

Class II. The special controls for this device are:

## Special Controls

*Classification.* Class II. The special controls for this device are:(1) FDA's:
(i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ”
(ii) “510(k) Sterility Review Guidance of 2/12/90 (K90-1),”
(iii) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone Cement,”
(iv) “Guidance Document for the Preparation of Premarket Notification (510(k)) Application for Orthopedic Devices,”
(v) “Guidance Document for Testing Non-articulating, ‘Mechanically Locked’ Modular Implant Components,”
(2) International Organization for Standardization's (ISO):
(i) ISO 5832-3:1996 “Implants for Surgery—Metallic Materials—Part 3: Wrought Titanium 6-Aluminum 4-Vandium Alloy,”
(ii) ISO 5832-4:1996 “Implants for Surgery—Metallic Materials—Part 4: Cobalt-Chromium-Molybdenum Casting Alloy,”
(iii) ISO 5832-12:1996 “Implants for Surgery—Metallic Materials—Part 12: Wrought Cobalt-Chromium-Molybdenum Alloy,”
(iv) ISO 5833:1992 “Implants for Surgery—Acrylic Resin Cements,”
(v) ISO 5834-2:1998 “Implants for Surgery—Ultra High Molecular Weight Polyethylene—Part 2: Moulded Forms,”
(vi) ISO 6018:1987 “Orthopaedic Implants—General Requirements for Marking, Packaging, and Labeling,”
(vii) ISO 9001:1994 “Quality Systems—Model for Quality Assurance in Design/Development, Production, Installation, and Servicing,” and
(viii) ISO 14630:1997 “Non-active Surgical Implants—General Requirements,”
(3) American Society for Testing and Materials':
(i) F 75-92 “Specification for Cast Cobalt-28 Chromium-6 Molybdenum Alloy for Surgical Implant Material,”
(ii) F 648-98 “Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants,”
(iii) F 799-96 “Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Forgings for Surgical Implants,”
(iv) F 981-93 “Practice for Assessment of Compatibility of Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,”
(v) F 1044-95 “Test Method for Shear Testing of Porous Metal Coatings,”
(vi) F 1108-97 “Specification for Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,”
(vii) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings, ” and
(viii) F 1537-94 “Specification for Wrought Cobalt-28 Chromium-6 Molybdenum Alloy for Surgical Implants.”

## Recent Cleared Devices (20 of 29)

Showing 20 most recent of 29 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K181362](/device/K181362.md) | TEMA Elbow System | Lima Corporate S.P.A. | Feb 16, 2019 | SESE |
| [K181307](/device/K181307.md) | Zimmer Nexel Total Elbow, Connrad/Morrey Total Elbow | Zimmer, Inc. | Jan 28, 2019 | SESE |
| [K153398](/device/K153398.md) | Comprehensive SRS/Nexel Elbow | Biomet Manufacturing Corp | Feb 3, 2016 | SESE |
| [K150501](/device/K150501.md) | Zimmer Nexel Total Elbow Ulnar Cement Diverter | Zimmer, Inc. | Apr 23, 2015 | SESE |
| [K123862](/device/K123862.md) | ZIMMER NEXEL TOTAL ELBOW | Zimmer, Inc. | Mar 12, 2013 | SESE |
| [K090473](/device/K090473.md) | DISCOVERY ELBOW - X-SMALL | Biomet Manufacturing Corp | Mar 25, 2009 | SESE |
| [K060696](/device/K060696.md) | ACCLAIM TOTAL ELBOW SYSTEM | DePuy Orthopaedics, Inc. | Apr 14, 2006 | SESE |
| [K053189](/device/K053189.md) | COONRAD/MORREY TOTAL ELBOW, MODEL 8105 SERIES | Zimmer, Inc. | Dec 9, 2005 | SESE |
| [K051975](/device/K051975.md) | POROUS COATED DISCOVERY ELBOW | Biomet, Inc. | Sep 6, 2005 | SESE |
| [K042664](/device/K042664.md) | LPS UPPER EXTREMITY | Depuy, Inc. | Dec 8, 2004 | SESE |
| [K040389](/device/K040389.md) | COONRAD/MORREY ELBOW CEMENT RESTRICTOR | Zimmer, Inc. | May 17, 2004 | SESE |
| [K033280](/device/K033280.md) | DISCOVERY ELBOW-MOSAIC DISTAL HUMERAL REPLACEMENT SYSTEM | Biomet, Inc. | Dec 19, 2003 | SESE |
| [K013042](/device/K013042.md) | DISCOVERY ELBOW | Biomet Orthopedics, Inc. | Oct 10, 2001 | SESE |
| [K003253](/device/K003253.md) | BIOMET'S MINIMALLY CONSTRAINED ELBOW | Biomet, Inc. | Jan 12, 2001 | SESE |
| [K000003](/device/K000003.md) | TORNIER TOTAL ELBOW PROSTHESIS | Tornier | Oct 2, 2000 | SESE |
| [K001989](/device/K001989.md) | COONRAD/MORREY TOTAL ELBOW. MODEL 32-8105 SERIES | Zimmer, Inc. | Jul 25, 2000 | SESE |
| [K000683](/device/K000683.md) | MODIFIED SINGLE AXLE TOTAL ELBOW | Biomet, Inc. | Jun 27, 2000 | SESE |
| [K992656](/device/K992656.md) | DEPUY TOTAL ELBOW SYSTEM | DePuy Orthopaedics, Inc. | Nov 5, 1999 | SESE |
| [K983036](/device/K983036.md) | SINGLE AXLE TOTAL ELBOW | Biomet, Inc. | Apr 30, 1999 | SESE |
| [K982398](/device/K982398.md) | BIOMET 100% POROUS COATED BIAXIAL TOTAL ELBOW | Biomet, Inc. | Aug 11, 1998 | SESE |

## Top Applicants

- Zimmer, Inc. — 8 clearances
- Biomet, Inc. — 7 clearances
- Biomet Manufacturing Corp — 2 clearances
- DePuy Orthopaedics, Inc. — 2 clearances
- Depuy, Inc. — 2 clearances

---

**Source:** [https://fda.innolitics.com/productcode/JDC](https://fda.innolitics.com/productcode/JDC)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com