INK · Stretcher, Wheeled, Powered

Physical Medicine · 21 CFR 890.3690 · Class 2

Overview

Product CodeINK
Device NameStretcher, Wheeled, Powered
Regulation21 CFR 890.3690
Device ClassClass 2
Review PanelPhysical Medicine
3rd-Party ReviewableYes

Identification

A powered wheeled stretcher is a battery-powered table with wheels that is intended for medical purposes for use by patients who are unable to propel themselves independently and who must maintain a prone or supine position for prolonged periods because of skin ulcers or contractures (muscle contractions).

Classification Rationale

Class II (performance standards). The powered wheeled stretcher is exempt from premarket notification procedures in subpart E of part 807 of this chapter, subject to § 890.9, and the following conditions for exemption:

Special Controls

(1) Appropriate analysis and nonclinical testing must demonstrate that the safety controls are adequate to ensure safe use of the device and prevent user falls from the device in the event of a device failure; (2) Appropriate analysis and nonclinical testing must demonstrate the ability of the device to withstand the rated user weight load with an appropriate factor of safety; (3) Appropriate analysis and nonclinical testing must demonstrate the longevity of the device to withstand external forces applied to the device and provide the user with an expected service life of the device; (4) Appropriate analysis and nonclinical testing must demonstrate proper environments of use and storage of the device to maximize the longevity of the device; (5) Appropriate analysis and nonclinical testing (such as outlined in appropriate FDA-recognized consensus standards) must validate electromagnetic compatibility and electrical safety; (6) Appropriate analysis and nonclinical testing (such as outlined in appropriate FDA-recognized consensus standards) must validate that the skin-contacting components of the device are biocompatible; (7) Appropriate analysis and nonclinical testing (such as outlined in appropriate FDA-recognized consensus standards) must validate the software life cycle and that all processes, activities, and tasks are implemented and documented; (8) Appropriate analysis and nonclinical testing must validate that the device components are found to be nonflammable; (9) Appropriate analysis and nonclinical testing (such as outlined in appropriate FDA-recognized consensus standards) must validate that the battery in the device performs as intended over the anticipated service life of the device; (10) Adequate labeling is provided to the user to document proper use and maintenance of the device to ensure safe use of the device in the intended use environment; and (11) Appropriate risk assessment including, but not limited to, evaluating the dimensional limits of the gaps in hospital beds, and mitigation strategy to reduce entrapment.

Recent Cleared Devices (12 of 12)

RecordDevice NameApplicantDecision DateDecision
K152056Winco Model S550 StretchairWinco Manufacturing, LLCApr 11, 2016SESE
K140095PRIME ZOOM STRETCHERStryker CorporationMay 20, 2014SESE
K112502PROCEDURAL STRECHER WITH INTELLIDRIVE P8000Hill-Rom Co.Sep 19, 2011SESE
K110671WINCO STRETCHAIRWinco Mfg., LLCApr 22, 2011SESE
K102236HOVERTRANS TRANSFORMER WITH POWER DRIVE MODEL HTT-650PD.T. Davis Enterprises Ltd. T/A Hovertech Int'LNov 18, 2010SESE
K091043POWER DRIVE CHAIR, MODEL: TMM6Transmotion Medical, Inc.May 11, 2009SESE
K051861THE SAVION INDUSTRIES MEDI-CRUISER MODEL MS777Savion Industries, Ltd.Sep 28, 2005SESE
K041924HAUSTED POWERTRAN SERIES STRETCHERSTERIS CorporationSep 9, 2004SESE
K022309STRYKER POWERED WHEELED STRETCHERStryker Corp.Nov 8, 2002SESE
K912175ISOTECHNOLOGIES LIFTSTATION & LIFTWORKS SOFTWAREIsotechnologies, Inc.Jun 7, 1991SESE
K844711MODELS 134, 135 & 136 TRANSFER CART/TABLETri W-G, Inc.Mar 5, 1985SESE
K771018TRANS 2000Hamilton Industries, Inc.Jul 14, 1977SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...