Browse hierarchy: [Obstetrics/Gynecology (OB)](/submissions/OB) → [Subpart E — Obstetrical and Gynecological Surgical Devices](/submissions/OB/subpart-e%E2%80%94obstetrical-and-gynecological-surgical-devices) → [21 CFR 884.4150](/submissions/OB/subpart-e%E2%80%94obstetrical-and-gynecological-surgical-devices/884.4150) → HIN — Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)

# HIN · Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)

_Obstetrics/Gynecology · 21 CFR 884.4150 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/HIN

## Overview

- **Product Code:** HIN
- **Device Name:** Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)
- **Regulation:** [21 CFR 884.4150](/submissions/OB/subpart-e%E2%80%94obstetrical-and-gynecological-surgical-devices/884.4150)
- **Device Class:** 2
- **Review Panel:** [Obstetrics/Gynecology](/submissions/OB)
- **3rd-party reviewable:** yes

## Identification

A bipolar endoscopic coagulator-cutter is a device used to perform female sterilization and other operative procedures under endoscopic observation. It destroys tissue with high temperatures by directing a high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and electrical cables.

## Classification Rationale

Class II. The special controls for this device are:

## Special Controls

*Classification.* Class II. The special controls for this device are:(1) FDA's:
(i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ”
(ii) “510(k) Sterility Review Guidance 2/12/90 (K-90),” and
(iii) “Guidance (‘Guidelines’) for Evaluation of Laproscopic Bipolar and Thermal Coagulators (and Accessories),”
(2) International Electrotechnical Commission's IEC 60601-1-AM2 (1995-03), Amendment 2, “Medical Electrical Equipment—Part 1: General Requirements for Safety,”
(3) American National Standards Institute/American Association for Medical Instrumentation's HF-18, 1993, “Electrosurgical Devices,”
(4) Labeling:
(i) Indication: For female tubal sterilization, and
(ii) Instructions for use:
(A) Destroy at least 2 centimeters of the fallopian tubes,
(B) Use a cut or undampened sinusoidal waveform,
(C) Use a minimum power of 25 watts, and
(D) For devices with ammeters: continue electrode activation for 5 seconds after the visual endpoint (tissue blanching) is reached or current flow ceases indicating adequate tissue destruction.

## Recent Cleared Devices (16 of 16)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K142525](/device/K142525.md) | PK Lap Loop | Olympus Winter & Ibe GmbH | Nov 21, 2014 | SESE |
| [K130305](/device/K130305.md) | LINA BIPOLAR LOOP; STANDARD SIZE, LARGE SIZE, EXTRA LARGE SIZE | Lina Medical Aps | Jul 24, 2013 | SESE |
| [K122983](/device/K122983.md) | KSEA BIPOLAR ELECTRODE | KARL STORZ Endoscopy-America, Inc. | Jun 26, 2013 | SESE |
| [K122605](/device/K122605.md) | PKS BILL | Gyrus Acmi, Inc. | Dec 5, 2012 | SESE |
| [K113080](/device/K113080.md) | TUBALGATOR | Mectra Labs, Inc. | Jun 29, 2012 | SESE |
| [K111751](/device/K111751.md) | VERSAPOINT II BIPOLAR ELECTROSURGERY GENERATOR, VERSAPOINT II 44MM ANGLED LOOP ELECTRODE, VERSAPOINT II FOOTSWITCH, VERS | ETHICON, Inc. | Dec 2, 2011 | SESE |
| [K111059](/device/K111059.md) | GYRUS ACMIL BIPOLARLAPROSCOPIC LOOP (PKS BILL) | Gyrus Acmi, Inc. | Sep 1, 2011 | SESE |
| [K990147](/device/K990147.md) | BIPOLAR FORCEPS, KLEPPINGER INSERT, MODEL #'S 8393.741,8393.771,8394.741,8394.771 | Richard Wolf Medical Instruments Corp. | Apr 16, 1999 | SESE |
| [K971565](/device/K971565.md) | BICOAG COAGULATING FORCEPS | Everest Medical Corp. | Mar 12, 1998 | SESE |
| [K926517](/device/K926517.md) | ELMED LBC 50-P | Elmed, Inc. | Nov 15, 1994 | SESE |
| [K943776](/device/K943776.md) | COAGULATOR CUTTER, ENDOSCOPIC BIPOLAR AND ACCESSORIES | Richard Wolf Medical Instruments Corp. | Nov 3, 1994 | SESE |
| [K911699](/device/K911699.md) | STI TISSUE MANIPULATOR | Surgical Technologies, Inc. | Jun 13, 1991 | SESE |
| [K871745](/device/K871745.md) | MODEL 26021C BIPOLAR COAGULATOR | KARL STORZ Endoscopy-America, Inc. | Jul 10, 1987 | SESE |
| [K790043](/device/K790043.md) | TRACOR, CANNULA, BICEPTS BIPOLAR | Neomed Corp. | Feb 8, 1979 | SESE |
| [K781109](/device/K781109.md) | FORCEPS, ELECTROSURGICAL | Kli | Sep 14, 1978 | SESE |
| [K781089](/device/K781089.md) | ONE INCISION BI-POLAR ELECTRO. FORCEPS | Kli | Jul 17, 1978 | SESE |

## Top Applicants

- Gyrus Acmi, Inc. — 2 clearances
- KARL STORZ Endoscopy-America, Inc. — 2 clearances
- Kli — 2 clearances
- Richard Wolf Medical Instruments Corp. — 2 clearances
- ETHICON, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/HIN](https://fda.innolitics.com/productcode/HIN)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
