Browse hierarchy: [Microbiology (MI)](/submissions/MI) → [Subpart D — Serological Reagents](/submissions/MI/subpart-d%E2%80%94serological-reagents) → [21 CFR 866.3510](/submissions/MI/subpart-d%E2%80%94serological-reagents/866.3510) → GOK — Antisera, Hai (Including Hai Control), Rubella

# GOK · Antisera, Hai (Including Hai Control), Rubella

_Microbiology · 21 CFR 866.3510 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/GOK

## Overview

- **Product Code:** GOK
- **Device Name:** Antisera, Hai (Including Hai Control), Rubella
- **Regulation:** [21 CFR 866.3510](/submissions/MI/subpart-d%E2%80%94serological-reagents/866.3510)
- **Device Class:** 2
- **Review Panel:** [Microbiology](/submissions/MI)
- **3rd-party reviewable:** yes

## Identification

Rubella virus serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to rubella virus in serum. The identification aids in the diagnosis of rubella (German measles) or confirmation of a person's immune status from past infections or immunizations and provides epidemiological information on German measles. Newborns infected in the uterus with rubella virus may be born with multiple congenital defects (rubella syndrome).

## Classification Rationale

Class II. The special controls for this device are:

## Special Controls

*Classification.* Class II. The special controls for this device are:(1) National Committee for Clinical Laboratory Standards':
(i) 1/LA6 “Detection and Quantitation of Rubella IgG Antibody: Evaluation and Performance Criteria for Multiple Component Test Products, Speciment Handling, and Use of the Test Products in the Clinical Laboratory, October 1997,”
(ii) 1/LA18 “Specifications for Immunological Testing for Infectious Diseases, December 1994,”
(iii) D13 “Agglutination Characteristics, Methodology, Limitations, and Clinical Validation, October 1993,”
(iv) EP5 “Evaluation of Precision Performance of Clinical Chemistry Devices, February 1999,” and
(v) EP10 “Preliminary Evaluation of the Linearity of Quantitive Clinical Laboratory Methods, May 1998,”
(2) Centers for Disease Control's:
(i) Low Titer Rubella Standard,
(ii) Reference Panel of Well Characterized Rubella Sera, and
(3) World Health Organization's International Rubella Standard.

## Recent Cleared Devices (11 of 11)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K832228](/device/K832228.md) | RUBASCAN LATEX CARD TEST | Bd Becton Dickinson Vacutainer Systems Preanalytic | Sep 29, 1983 | SESE |
| [K810835](/device/K810835.md) | RUBAZYME - M | Abbott Laboratories | May 5, 1981 | SESE |
| [K792635](/device/K792635.md) | ANTIBODY TO RUBELLA VIRUS | Electro-Nucleonics Laboratories, Inc. | Mar 19, 1980 | SESE |
| [K792133](/device/K792133.md) | RUBELISA TEST KIT | Microbiological Assoc. | Jan 11, 1980 | SESE |
| [K790122](/device/K790122.md) | RUBANON | Organon, Inc. | Feb 15, 1979 | SESE |
| [K781638](/device/K781638.md) | RUBINDEX*DIRECT SYSTEM | Ortho Diagnostics, Inc. | Dec 20, 1978 | SESE |
| [K781392](/device/K781392.md) | CYTOMEGILISH TEST KIT | Microbiological Assoc. | Oct 24, 1978 | SESE |
| [K780063](/device/K780063.md) | RUBENOSTICON | Organon, Inc. | Jan 20, 1978 | SESE |
| [K780010](/device/K780010.md) | GOAT ANTI-RUBELLA ANTISERA | Northeast Biomedical Labs., Inc. | Jan 20, 1978 | SESE |
| [K771957](/device/K771957.md) | RUBELLA HEMAGGLUTINATION REAGENT KIT | Flow Laboratories, Inc. | Oct 28, 1977 | SESE |
| [K771956](/device/K771956.md) | HUMAN O BUFFER | Flow Laboratories, Inc. | Oct 28, 1977 | SESE |

## Top Applicants

- Flow Laboratories, Inc. — 2 clearances
- Microbiological Assoc. — 2 clearances
- Organon, Inc. — 2 clearances
- Abbott Laboratories — 1 clearance
- Bd Becton Dickinson Vacutainer Systems Preanalytic — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/GOK](https://fda.innolitics.com/productcode/GOK)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
