# GHQ · Stain, Fetal Hemoglobin

_Hematology · 21 CFR 864.7455 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/GHQ

## Overview

- **Product Code:** GHQ
- **Device Name:** Stain, Fetal Hemoglobin
- **Regulation:** [21 CFR 864.7455](/submissions/HE/subpart-h%E2%80%94hematology-kits-and-packages/864.7455)
- **Device Class:** 2
- **Review Panel:** [Hematology](/submissions/HE)

## Identification

A fetal hemoglobin assay is a device that is used to determine the presence and distribution of fetal hemoglobin (hemoglobin F) in red cells or to measure the amount of fetal hemoglobin present. The assay may be used to detect fetal red cells in the maternal circulation or to detect the elevated levels of fetal hemoglobin exhibited in cases of hemoglobin abnormalities such as thalassemia (a hereditary hemolytic anemia characterized by a decreased synthesis of one or more types of hemoglobin polypeptide chains). The hemoglobin determination may be made by methods such as electrophoresis, alkali denaturation, column chromatography, or radial immunodiffusion.

## Classification Rationale

Class II (special controls). A fetal hemoglobin stain intended for use with a fetal hemoglobin assay is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

## Special Controls

*Classification.* Class II (special controls). A fetal hemoglobin stain intended for use with a fetal hemoglobin assay is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

## Recent Cleared Devices (2 of 2)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K990641](/device/K990641.md) | CALTAG FETAL HEMOGLOBIN TEST | Caltag Laboratories, Inc. | Sep 17, 1999 | SESE |
| [K892241](/device/K892241.md) | FETAL HEMOGLOBIN | Sure-Tech Diagnostic Associates, Inc. | May 17, 1989 | SESE |

## Top Applicants

- Caltag Laboratories, Inc. — 1 clearance
- Sure-Tech Diagnostic Associates, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/GHQ](https://fda.innolitics.com/productcode/GHQ)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).