Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart B — Diagnostic Devices](/submissions/GU/subpart-b%E2%80%94diagnostic-devices) → [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500) → GCI — Laryngoscope, Endoscope

# GCI · Laryngoscope, Endoscope

_Gastroenterology, Urology · 21 CFR 876.1500 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/GCI

## Overview

- **Product Code:** GCI
- **Device Name:** Laryngoscope, Endoscope
- **Regulation:** [21 CFR 876.1500](/submissions/GU/subpart-b%E2%80%94diagnostic-devices/876.1500)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

## Recent Cleared Devices (14 of 14)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K021747](/device/K021747.md) | DEGALL LAPAROSCOPIC GALLBLADDER EXTRACTOR | Surgicon, Inc. | Aug 15, 2002 | SESE |
| [K003222](/device/K003222.md) | MODIFICATION TO HERMES OPERATING ROOM CONTROL CENTER | Computer Motion, Inc. | Nov 3, 2000 | SESE |
| [K001362](/device/K001362.md) | KARL STORZ 3D VIDEO SYSTEM | Karl Storz Imaging, Inc. | Jul 17, 2000 | SESE |
| [K933515](/device/K933515.md) | BOOTY ENDOSCOPE WARMER | T-Med, Inc. | Oct 27, 1993 | SESE |
| [K930302](/device/K930302.md) | BIRTCHER SURE CLEAN INSTRUMENT SYSTEM | Birtcher Medical Systems, Inc. | Oct 27, 1993 | SESE |
| [K930496](/device/K930496.md) | GI-1090,1095,1080,1085,1086,1088, ENDO. CLAMPS | Birtcher Medical Systems, Inc. | Apr 20, 1993 | SESE |
| [K922123](/device/K922123.md) | AUTO SUTURE DISPOSABLE ENDOSCOPIC SPECIMEN POUCH | United States Surgical, A Division of Tyco Healthc | Feb 1, 1993 | SESE |
| [K920139](/device/K920139.md) | GLEESON CLOT-BUSTER | Conmedcorp | Apr 15, 1992 | SESE |
| [K915762](/device/K915762.md) | POOLE TIP SUCTION PROBE | O.R. Concepts, Inc. | Mar 13, 1992 | SESE |
| [K914120](/device/K914120.md) | SINGLE USE LAPAROSCOPY ELECTROSURGICAL INSTRUMENT | Conmedcorp | Oct 30, 1991 | SESE |
| [K911829](/device/K911829.md) | ENDOSTAPLE | ETHICON, Inc. | Aug 28, 1991 | SESE |
| [K911461](/device/K911461.md) | SURGITRON | Ellman Intl. Mfg., Inc. | Apr 25, 1991 | SESE |
| [K905117](/device/K905117.md) | ENDOSCOPE AND ACCESSORIES | Northgate Technologies, Inc. | Apr 25, 1991 | SESE |
| [K896205](/device/K896205.md) | MONOSCOPY BRAND, 5 MM LOCKING TROCAR SLEEVE | Dexide, Inc. | Mar 22, 1990 | SESE |

## Top Applicants

- Birtcher Medical Systems, Inc. — 2 clearances
- Conmedcorp — 2 clearances
- Computer Motion, Inc. — 1 clearance
- Dexide, Inc. — 1 clearance
- ETHICON, Inc. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/GCI](https://fda.innolitics.com/productcode/GCI)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).