Browse hierarchy: [General Hospital (HO)](/submissions/HO) → [Subpart F — General Hospital and Personal Use Therapeutic Devices](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices) → [21 CFR 880.5130](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/880.5130) → FMT — Warmer, Infant Radiant

# FMT · Warmer, Infant Radiant

_General Hospital · 21 CFR 880.5130 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/FMT

## Overview

- **Product Code:** FMT
- **Device Name:** Warmer, Infant Radiant
- **Regulation:** [21 CFR 880.5130](/submissions/HO/subpart-f%E2%80%94general-hospital-and-personal-use-therapeutic-devices/880.5130)
- **Device Class:** 2
- **Review Panel:** [General Hospital](/submissions/HO)
- **3rd-party reviewable:** yes

## Identification

The infant radiant warmer is a device consisting of an infrared heating element intended to be placed over an infant to maintain the infant's body temperature by means of radiant heat. The device may also contain a temperature monitoring sensor, a heat output control mechanism, and an alarm system (infant temperature, manual mode if present, and failure alarms) to alert operators of a temperature condition over or under the set temperature, manual mode time limits, and device component failure, respectively. The device may be placed over a pediatric hospital bed or it may be built into the bed as a complete unit.

## Classification Rationale

Class II (Special Controls)

## Special Controls

*Classification.* Class II (Special Controls):(1) The Association for the Advancement of Medical Instrumentation (AAMI) Voluntary Standard for the Infant Radiant Warmer;
(2) A prescription statement in accordance with § 801.109 of this chapter (restricted to use by or upon the order of qualified practitioners as determined by the States); and
(3) Labeling for use only in health care facilities and only by persons with specific training and experience in the use of the device.

## Recent Cleared Devices (20 of 92)

Showing 20 most recent of 92 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K243606](/device/K243606.md) | Babyroo TN300 | Draeger Medical Systems, Inc. | Jan 17, 2025 | SESE |
| [K230278](/device/K230278.md) | Babyroo TN300 | Draeger Medical Systems, Inc. | May 30, 2023 | SESE |
| [K213551](/device/K213551.md) | Giraffe Omnibed Carestation CS1 | Datex Ohmeda, Inc. | Mar 2, 2022 | SESE |
| [K201628](/device/K201628.md) | Panda iRes Warmer, Giraffe Warmer | GE Healthcare | Feb 12, 2021 | SESE |
| [K200319](/device/K200319.md) | HYDRO-TEMP Neonatal Skin Surface Temperature Sensor, HYDRO-TEMP Neonatal Skin Surface Temperature Sensor with Interface Cable | Deroyal Industries, Inc. | Apr 2, 2020 | SESE |
| [K191425](/device/K191425.md) | Hydro-Temp Neonatal Skin Temperature Probe Cover | Deroyal Industries, Inc. | Jan 21, 2020 | SESE |
| [K173516](/device/K173516.md) | NuBorne Infant Warmer | International Biomedical | Aug 17, 2018 | SESE |
| [K123309](/device/K123309.md) | GIRAFFE AND PANDA WARMERS | Ohmeda Medical | Feb 5, 2013 | SESE |
| [K120642](/device/K120642.md) | RESUSCITAIRE WITH AUTOBREATH | Draeger Medical Systems, Inc. | Nov 2, 2012 | SESE |
| [K122267](/device/K122267.md) | GIRAFFE AND PANDA WARMERS | Ohmeda Medical, A Division of Datex-Ohmeda, Inc. | Oct 2, 2012 | SESE |
| [K121625](/device/K121625.md) | LULLABY TM WARMER | Wipro GE Healthcare Private, Ltd. | Sep 14, 2012 | SESE |
| [K120937](/device/K120937.md) | SUNFLOWER WARNER | Atom Medical Corporation | Jul 6, 2012 | SESE |
| [K102227](/device/K102227.md) | INFA WARMER I | Atom Medical Corporation | Jan 21, 2011 | SESE |
| [K101804](/device/K101804.md) | GIRAFFE AND PANDA WARMERS | Ohmeda Medical, A Division of Datex-Ohmeda, Inc. | Jul 21, 2010 | SESE |
| [K090697](/device/K090697.md) | MODIFICATION TO: GIRAFFE AND PANDA WARMER | Ohmeda Medical | Apr 16, 2009 | SESE |
| [K072157](/device/K072157.md) | MODIFICATION TO GIRAFFE AND PANDA WARMERS (GIRAFFE AND PANDA UNINTERRUPTIBLE POWER SUPPLY) | Ohmeda Medical | Aug 27, 2007 | SESE |
| [K070377](/device/K070377.md) | GIRAFFE AND PANDA WARMER | Ohmeda Medical | Jul 11, 2007 | SESE |
| [K060461](/device/K060461.md) | V-505 INFA WARMER | Atom Medical, Inc. | Apr 28, 2006 | SESE |
| [K033040](/device/K033040.md) | PHOENIX INFANT RADIANT WARMER, MODEL 100NWS | International Hospital Supply Co. | Dec 17, 2003 | SESE |
| [K020966](/device/K020966.md) | RPI REPLACEMENT HEATING ELEMENTS | Replacement Parts Industries, Inc. | Jun 13, 2002 | SESE |

## Top Applicants

- Ohmeda Medical — 10 clearances
- Contour Medical Technology, Inc. — 6 clearances
- Air-Shields, Inc. — 5 clearances
- Fisher & Paykel Electronics , Ltd. — 4 clearances
- Gempco, Inc. — 4 clearances

---

**Source:** [https://fda.innolitics.com/productcode/FMT](https://fda.innolitics.com/productcode/FMT)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
