# FKX · System, Peritoneal, Automatic Delivery

_Gastroenterology, Urology · 21 CFR 876.5630 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/FKX

## Overview

- **Product Code:** FKX
- **Device Name:** System, Peritoneal, Automatic Delivery
- **Regulation:** [21 CFR 876.5630](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5630)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **Life-sustaining:** yes

## Identification

(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.

## Classification Rationale

Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

## Special Controls

*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

## Recent Cleared Devices (20 of 83)

Showing 20 most recent of 83 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K250523](/device/K250523.md) | Archimedes Pro Automated Peritoneal Dialysis Cycler (3014-00000-1); Archimedes Standard Automated Peritoneal Dialysis Cycler (3014-00000-3); Archimedes Pro Disposable Tubing Set (3014-50000-1); Archimedes Standard Disposable Tubing Set (3014-50000-3); Archimedes Pro Plus Disposable Tubing Set (3014-50000-5) | Simergent, LLC | Oct 2, 2025 | SESE |
| [K243371](/device/K243371.md) | Byonyks X-1 APD Cycler; Byonyks Automated PD Set DS-1 | Byonyks Pvt, Ltd. | May 16, 2025 | SESE |
| [K220935](/device/K220935.md) | Digital Dialysis Clinic - Intelligent Dialysis Assistant (IDA) with Medical Supervision Portal and IDA Smartphone App | Iren-Medical, Ltd. | Dec 29, 2022 | SESE |
| [K222318](/device/K222318.md) | Fresenius Liberty Select Cycler | Fresenius Medical Care Renal Therapies Group, LLC | Oct 31, 2022 | SESE |
| [K212522](/device/K212522.md) | Lilliput APD System | Fresenius Medical Care Renal Therapies Group, LLC | Apr 15, 2022 | SESE |
| [K212658](/device/K212658.md) | CloudCath Peritoneal Dialysis Drain Set Monitoring System | Cloudcath | Feb 9, 2022 | SESE |
| [K201867](/device/K201867.md) | Homechoice Claria APD System, Sharesource Connectivity Platform for Use with the Homechoice Claria APD System | Baxter Healthcare Corporation | Nov 19, 2020 | SESE |
| [K181108](/device/K181108.md) | Fresenius Liberty Select Cycler | Fresenius Medical Care Renal Therapies Group, LLC | May 24, 2018 | SESE |
| [K173718](/device/K173718.md) | Liberty Cycler Set | Fresenius Medical Care Renal Therapies Group, LLC | May 1, 2018 | SESE |
| [K171652](/device/K171652.md) | Fresenius Liberty Select Cycler | Fresenius Medical Care Renal Therapies Group, LLC | Sep 15, 2017 | SESE |
| [K151525](/device/K151525.md) | Amia Automated PD System with Sharesource | Deka Research and Development | Oct 9, 2015 | SESE |
| [K141145](/device/K141145.md) | LIBERTY PDX CYCLER | Fresenius Medical Care Renal Therapies Group, LLC | Jul 30, 2014 | SESE |
| [K123630](/device/K123630.md) | FRESENIUS LIBERTY CYCLER | Fresenius Medical Care North America, Design Cente | Sep 9, 2013 | SESE |
| [K124018](/device/K124018.md) | AMIA AUTOMATED PD SYSTEM | Deka Research & Development Corp. | Jun 14, 2013 | SESE |
| [K103220](/device/K103220.md) | VOYAGER PERITONEAL DIALYSIS SYSTEM | Deka Research & Development Corp. | Jul 29, 2011 | SESE |
| [K102936](/device/K102936.md) | HOMECHOICE/HOMECHOICE PRO AUTOMATED PERSONAL CYCLER PERITONEAL DIALYSIS SYSTEM MODEL 5C4471, 5C8310, 5C4471R AND 5C8310R | Baxter Healthcare Corp | Mar 30, 2011 | SESE |
| [K053512](/device/K053512.md) | HOMECHOICE/HOMECHOICE PRO PERSONAL CYCLER PERITONEAL DIALYSIS SYSTEM, MODELS 5C4471 AND 5C8310 | Baxter Healthcare Corp | Feb 16, 2006 | SESE |
| [K043363](/device/K043363.md) | FRESENIUS LIBERTY CYCLER | Fresenius Medical Care North America | Mar 31, 2005 | SESE |
| [K012988](/device/K012988.md) | HOMECHOICE PERSONAL CYCLER PERITONEAL DIALYSIS SYSTEM, MODELS 5C8310, 5C8302, 5C4471, 5C4469 | Baxter Healthcare Corp | Dec 5, 2001 | SESE |
| [K002892](/device/K002892.md) | FRSENIUS PD IQCARD CYCLER | Fresenius Medical Care North America | Apr 5, 2001 | SESE |

## Top Applicants

- American Medical Products, Inc. — 11 clearances
- Travenol Laboratories, S.A. — 8 clearances
- Abbott Laboratories — 6 clearances
- Baxter Healthcare Corp — 6 clearances
- Fresenius Medical Care Renal Therapies Group, LLC — 6 clearances

---

**Source:** [https://fda.innolitics.com/productcode/FKX](https://fda.innolitics.com/productcode/FKX)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).