Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5820](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5820) → FKP — System, Dialysate Delivery, Single Patient

# FKP · System, Dialysate Delivery, Single Patient

_Gastroenterology, Urology · 21 CFR 876.5820 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/FKP

## Overview

- **Product Code:** FKP
- **Device Name:** System, Dialysate Delivery, Single Patient
- **Regulation:** [21 CFR 876.5820](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5820)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **Life-sustaining:** yes

## Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

## Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

## Recent Cleared Devices (20 of 50)

Showing 20 most recent of 50 cleared devices.

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K181991](/device/K181991.md) | NxStage Connected Health System | Nxstage Medical, Inc. | Sep 26, 2018 | SESE |
| [K131739](/device/K131739.md) | NXSTAGE CONNECTED HEALTH SYSTEM | Nxstage Medical, Inc. | Oct 10, 2013 | SESE |
| [K130460](/device/K130460.md) | NXSTAGE DOSING CALCULATOR | Nxstage Medical, Inc. | Jul 11, 2013 | SESE |
| [K040074](/device/K040074.md) | ONEVIEW INTERFACE | Nxstage Medical, Inc. | Apr 8, 2004 | SESE |
| [K021060](/device/K021060.md) | FRESENIUS ICARE MONITORING SYSTEM | Fresenius Medical Care North America | Nov 13, 2002 | SESE |
| [K003615](/device/K003615.md) | STERICHEK SENSITIVE-FEED WATER AND RINSE WATER REAGENT STRIPS | Environmental Test Systems, Inc. | Feb 1, 2001 | SESE |
| [K992255](/device/K992255.md) | CKHEMO, MODEL CKHEMO VERSION 1.0 | Csam, Inc. | Nov 30, 1999 | SESE |
| [K964264](/device/K964264.md) | HIGH RANGE PEROXIDE TEST STRIP | Integrated Biomedical Technology, Inc. | Jun 16, 1997 | SESE |
| [K955423](/device/K955423.md) | PACK H HEMODIALYSIS UREA KINETIC MODELING SOFTWARE PROGRAM | Fresenius USA, Inc. | Jun 13, 1996 | SESE |
| [K953854](/device/K953854.md) | WATERCHECK REAGENT STRIP FOR CHLORINE & PEROXIDE | Integrated Biomedical Technology, Inc. | Mar 11, 1996 | SESE |
| [K930181](/device/K930181.md) | BIOPURE DIALYSATE CONCENTRATE MIX SYST/CONCENTRATE | Fresenius USA, Inc. | Nov 29, 1995 | SESE |
| [K922757](/device/K922757.md) | SPS 1550 SINGLE NEEDLE PATIENT SYSTEM | Baxter Healthcare Corp | Feb 13, 1995 | SESE |
| [K921456](/device/K921456.md) | FRESENIUS 3008/FDS-08 DIALYSATE DELIVERY SYSTEM | Fresenius USA, Inc. | Apr 20, 1994 | SESE |
| [K910215](/device/K910215.md) | DRAKE WILLOCK SYSTEM 1000 DIALYSATE DELIVERY SYST | Cd Medical, Inc. | Apr 9, 1991 | SESE |
| [K905793](/device/K905793.md) | COBE CENTRY 2 BICART OPTION KIT | Cobe Laboratories, Inc. | Feb 12, 1991 | SESE |
| [K905388](/device/K905388.md) | COBE CENTRYSYSTEM 3 BICART OPTION KIT | Cobe Laboratories, Inc. | Feb 11, 1991 | SESE |
| [K904967](/device/K904967.md) | HOSPAL BICART RETROFIT KIT NA/MONIT S GS HEMODIAL | Gambro-Hosp-Cobe, Inc. | Jan 28, 1991 | SESE |
| [K896758](/device/K896758.md) | GAMBRO BICARBONATE MONITOR BCM 10-3 | Gambro, Inc. | Sep 28, 1990 | SESE |
| [K896757](/device/K896757.md) | GAMBRO AK-10 DIALYSIS SYSTEM FOR HIGH FLOWS | Gambro, Inc. | Aug 30, 1990 | SESE |
| [K894838](/device/K894838.md) | HEMODIALYSIS SINGLE PATIENT SYSTEM (SPS) 550 VSB | Baxter Healthcare Corp | Sep 7, 1989 | SESE |

## Top Applicants

- Gambro, Inc. — 6 clearances
- Cobe Laboratories, Inc. — 4 clearances
- Extracorporeal Medical Specialities, Inc. — 4 clearances
- Fresenius USA, Inc. — 4 clearances
- Nxstage Medical, Inc. — 4 clearances

---

**Source:** [https://fda.innolitics.com/productcode/FKP](https://fda.innolitics.com/productcode/FKP)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
