Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5630](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5630) → FKO — Catheter, Peritoneal Dialysis, Single Use

# FKO · Catheter, Peritoneal Dialysis, Single Use

_Gastroenterology, Urology · 21 CFR 876.5630 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/FKO

## Overview

- **Product Code:** FKO
- **Device Name:** Catheter, Peritoneal Dialysis, Single Use
- **Regulation:** [21 CFR 876.5630](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5630)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **Life-sustaining:** yes

## Identification

(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.

## Classification Rationale

Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

## Special Controls

*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

## Recent Cleared Devices (16 of 16)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K964514](/device/K964514.md) | CORPAK MEDSYSTEMS CRUZ CATHETER FOR PERITONEAL DIALYSIS | Corpak, Inc. | Jun 26, 1998 | SESE |
| [K974570](/device/K974570.md) | PERITONEAL DIALYSIS CATHETER CONNECTOR | Medigroup, Inc. | Feb 27, 1998 | SESE |
| [K910787](/device/K910787.md) | TITANIUM CONNECTOR (2 PART) | Accurate Surgical Instruments Co. | Aug 15, 1991 | SESE |
| [K885037](/device/K885037.md) | AMUKIN 50% - AIRSPRAY(R) | Bernard J. Cooney, P.A. | Oct 19, 1990 | SESE |
| [K874650](/device/K874650.md) | PERITONEAL DIALYSIS KIT (ACUTE AND CHRONIC FORM) | Quinton, Inc. | Dec 9, 1987 | SESE |
| [K872221](/device/K872221.md) | DIALY-NATE SET & DIALY-NATE CATHETER | Gesco Intl., Inc. | Oct 13, 1987 | SESE |
| [K871730](/device/K871730.md) | MODIFIED USE OF PULL-APART INTRODUCER SET | Quinton, Inc. | May 18, 1987 | SESE |
| [K870472](/device/K870472.md) | ACUTE PERITONEAL DIALYSIS KIT | Quinton, Inc. | Feb 25, 1987 | SESE |
| [K860155](/device/K860155.md) | PERITONEAL LAVAGE CATH PLC-8,SET PLS-8, KIT PLK-8 | Medical Components, Inc. | Feb 14, 1986 | SESD |
| [K854966](/device/K854966.md) | ACUTE PERITONEAL DIALYSIS CATHETERS | Thermedics, Inc. | Jan 9, 1986 | SESE |
| [K845041](/device/K845041.md) | CAPD STAGED CONNECTOR | Abbott Laboratories | Feb 21, 1985 | SESE |
| [K813336](/device/K813336.md) | LAZARUS-NELSON PERITONEAL LAVAGE TRAY | American Pharmaseal Div. Ahsc | Dec 18, 1981 | SESE |
| [K812717](/device/K812717.md) | NON-STERILE SHADOW-STRIPE CATHETER | Quinton, Inc. | Oct 19, 1981 | SESE |
| [K811266](/device/K811266.md) | QUINTON CATHETER FINGER GRIP | Quinton, Inc. | Jun 18, 1981 | SESE |
| [K802954](/device/K802954.md) | DRESSING CHANGE TRAY-MEDIUM | Associated Medical Products Co. | Dec 17, 1980 | SESE |
| [K760544](/device/K760544.md) | CATHETER, PERITONEAL DIALYSIS | Travenol Laboratories, S.A. | Oct 20, 1976 | SESE |

## Top Applicants

- Quinton, Inc. — 5 clearances
- Abbott Laboratories — 1 clearance
- Accurate Surgical Instruments Co. — 1 clearance
- American Pharmaseal Div. Ahsc — 1 clearance
- Associated Medical Products Co. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/FKO](https://fda.innolitics.com/productcode/FKO)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
