Browse hierarchy: [Gastroenterology, Urology (GU)](/submissions/GU) → [Subpart F — Therapeutic Devices](/submissions/GU/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 876.5820](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5820) → FIN — Tank, Holding, Dialysis

# FIN · Tank, Holding, Dialysis

_Gastroenterology, Urology · 21 CFR 876.5820 · Class 2_

**Canonical URL:** https://fda.innolitics.com/productcode/FIN

## Overview

- **Product Code:** FIN
- **Device Name:** Tank, Holding, Dialysis
- **Regulation:** [21 CFR 876.5820](/submissions/GU/subpart-f%E2%80%94therapeutic-devices/876.5820)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

## Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

## Recent Cleared Devices (18 of 18)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K140984](/device/K140984.md) | TANGO3 WATER STORAGE TANK WITH OZONE DISINFECTION SYSTEM | Tango3, LLC | Jan 12, 2015 | SESE |
| [K141213](/device/K141213.md) | AMERIWATER OZONE DISINFECTION SYSTEM | Ameriwater | Dec 10, 2014 | SESE |
| [K112427](/device/K112427.md) | BICARB MIXING AND DISTRIBUTION SYSTEM | Isopure, Corp. | Jan 26, 2012 | SESE |
| [K093641](/device/K093641.md) | TANGO3 WATER STORAGE TANK WITH OZONE DISINFECTION SYSTEM | Tango3, LLC | Dec 8, 2010 | SESE |
| [K060333](/device/K060333.md) | DIALYSIS SERVICES, INC., TYPHOON BICARB MIXING AND DISTRIBUTION SYSTEM | Dialysis Services, Inc. | Sep 8, 2006 | SESE |
| [K051031](/device/K051031.md) | AMERIWATER SOLUTION MIX AND DISTRIBUTION SYSTEM FOR HEMODIALYSIS | Ameriwater | Jan 6, 2006 | SESE |
| [K031502](/device/K031502.md) | USFILTER BICARBONATE MIXING AND DISPENSING (BICARB) SYSTEM | Usfilter | Aug 27, 2004 | SESE |
| [K033118](/device/K033118.md) | BIPRO MODEL SDS-CB200 | Medical Solutions International | Jun 28, 2004 | SESE |
| [K030366](/device/K030366.md) | BICARD MIXING SYSTEM | Dialysis Systems, Inc. | Apr 19, 2004 | SESE |
| [K023011](/device/K023011.md) | OSMONICS SOLUTION DELIVERY SYSTEM | Osmonics Medical Systems | Jun 26, 2003 | SESE |
| [K003560](/device/K003560.md) | MAR COR SERVICES BICARB SYSTEM | Mar Cor Services, Inc. | Jun 8, 2001 | SESE |
| [K993272](/device/K993272.md) | PURE WATER, INC.'S BICARB MIX, STORAGE AND DISTRIBUTION SYSTEM | Pure Water, Inc. | Apr 10, 2000 | SESE |
| [K993058](/device/K993058.md) | PURE WATER INC'S ACIDIFIED STORAGE AND DISTRIBUTION SYSTEM WITH OPTIONAL REMOTE FILL | Pure Water, Inc. | Jan 24, 2000 | SESE |
| [K992793](/device/K992793.md) | SODIUM BICARBONATE MIXING/DELIVERY SYSTEM, AND THE CONCENTRATE DELIVERY SYSTEM | Better Water, Inc. | Nov 16, 1999 | SESE |
| [K970674](/device/K970674.md) | G.E.M. WATER SYSTEMS, INTERNATIONAL | G.E.M. Water Systems | Nov 19, 1997 | SESE |
| [K961416](/device/K961416.md) | DIALYSIS MIXING & HOLDING TANK | Dial Medical Supply | Aug 21, 1996 | SESE |
| [K883408](/device/K883408.md) | NATURALYTE MIXER | National Medical Care, Medical Products Div., Inc. | Oct 31, 1988 | SESE |
| [K873166](/device/K873166.md) | BCM DRY PACK BICARBONATE MIXER | Specialty Dialysis Services | Dec 30, 1987 | SESE |

## Top Applicants

- Ameriwater — 2 clearances
- Pure Water, Inc. — 2 clearances
- Tango3, LLC — 2 clearances
- Better Water, Inc. — 1 clearance
- Dial Medical Supply — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/FIN](https://fda.innolitics.com/productcode/FIN)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
