## Overview

- **Product Code:** FEO
- **Device Name:** Lithotriptor, Ultrasonic
- **Regulation:** [21 CFR 876.4480](/submissions/GU/subpart-e%E2%80%94surgical-devices/876.4480)
- **Device Class:** 2
- **Review Panel:** [Gastroenterology, Urology](/submissions/GU)
- **3rd-party reviewable:** yes

## Identification

An electrohydraulic lithotriptor is an AC-powered device used to fragment urinary bladder stones. It consists of a high voltage source connected by a cable to a bipolar electrode that is introduced into the urinary bladder through a cystoscope. The electrode is held against the stone in a water-filled bladder and repeated electrical discharges between the two poles of the electrode cause electrohydraulic shock waves which disintegrate the stone.

## Classification Rationale

Class II. The special control for this device is FDA's “Guidance for the Content of Premarket Notifications for Intracorporeal Lithotripters.”

## Special Controls

The special control for this device is FDA's “Guidance for the Content of Premarket Notifications for Intracorporeal Lithotripters.”

## Recent Cleared Devices (14 of 14)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K230893](/device/K230893.md) | Swiss LthoClast Trilogy | E.M.S Electro Medical Systems S.A | Oct 23, 2023 | SESE |
| [K182490](/device/K182490.md) | Swiss LithoClast Trilogy | E.M.S Electro Medical Systems S.A | Oct 9, 2018 | SESE |
| [K181997](/device/K181997.md) | Swiss LithoClast Trilogy | E.M.S Electro Medical Systems S.A | Aug 30, 2018 | SESE |
| [K181364](/device/K181364.md) | Swiss LithoClast Trilogy | E.M.S Electro Medical Systems S.A | Jun 20, 2018 | SESE |
| [K173234](/device/K173234.md) | Swiss LithoClast Trilogy | E.M.S Electro Medical Systems S.A | Jan 10, 2018 | SESE |
| [K171024](/device/K171024.md) | ShockPulse-SE Lithotripsy System | Cybersonics, Inc. | Aug 21, 2017 | SESE |
| [K142428](/device/K142428.md) | Shock Pulse-SE Lithotripsy System CYBERWAND II | Cybersonics, Inc. | Nov 13, 2014 | SESE |
| [K993046](/device/K993046.md) | FIBRA SONICS ULTRASONIC LITHOTRIPTOR LITHOSONIC, MODEL LS-2000 | Fibra Sonics, Inc. | Nov 22, 1999 | SESE |
| [K973251](/device/K973251.md) | KSEA CALCUSON | KARL STORZ Endoscopy-America, Inc. | Jun 22, 1998 | SESE |
| [K920235](/device/K920235.md) | ULTRASOUND GENERATOR MODLE 2270 | Richard Wolf Medical Instruments Corp. | Dec 7, 1992 | SESE |
| [K873367](/device/K873367.md) | OLYMPUS LUS ULTRASONIC LITHOTRIPTER | Olympus Corp. | Nov 30, 1987 | SESE |
| [K850298](/device/K850298.md) | ULTRALITH ULTRASONIC LITHOTRIPSY SYSTEM | Cabot Medical Corp. | Mar 5, 1985 | SESE |
| [K843101](/device/K843101.md) | KARL STORZ 27086KC ULTRASONIC LITHOTRI | KARL STORZ Endoscopy-America, Inc. | Dec 11, 1984 | SESE |
| [K842024](/device/K842024.md) | ULTRASONIC LITHOTRIPTOR 300A | Fibra Sonics, Inc. | Dec 11, 1984 | SESE |

## Top Applicants

- E.M.S Electro Medical Systems S.A — 5 clearances
- Cybersonics, Inc. — 2 clearances
- Fibra Sonics, Inc. — 2 clearances
- KARL STORZ Endoscopy-America, Inc. — 2 clearances
- Cabot Medical Corp. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/FEO](https://fda.innolitics.com/productcode/FEO)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).