Browse hierarchy: [Clinical Chemistry (CH)](/submissions/CH) → [Subpart C — Clinical Laboratory Instruments](/submissions/CH/subpart-c%E2%80%94clinical-laboratory-instruments) → [21 CFR 862.2270](/submissions/CH/subpart-c%E2%80%94clinical-laboratory-instruments/862.2270) → DKG — Plate, Cellulose, Tlc

# DKG · Plate, Cellulose, Tlc

_Clinical Chemistry · 21 CFR 862.2270 · Class 1_

**Canonical URL:** https://fda.innolitics.com/productcode/DKG

## Overview

- **Product Code:** DKG
- **Device Name:** Plate, Cellulose, Tlc
- **Regulation:** [21 CFR 862.2270](/submissions/CH/subpart-c%E2%80%94clinical-laboratory-instruments/862.2270)
- **Device Class:** 1
- **Review Panel:** [Clinical Chemistry](/submissions/CH)

## Identification

A thin-layer chromatography (TLC) system for clinical use is a device intended to separate one or more drugs or compounds from a mixture. The mixture of compounds is absorbed onto a stationary phase or thin layer of inert material (e.g., cellulose, alumina, etc.) and eluted off by a moving solvent (moving phase) until equilibrium occurs between the two phases.

## Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 862.9. Particular components of TLC systems,i.e., the thin-layer chromatography apparatus, TLC atomizer, TLC developing tanks, and TLC ultraviolet light, are exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

## Recent Cleared Devices (1 of 1)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K894327](/device/K894327.md) | EMIT D.A.U. LOW & MEDIUM CALIBRATOR A | Syva Co. | Aug 3, 1989 | SESE |

## Top Applicants

- Syva Co. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/DKG](https://fda.innolitics.com/productcode/DKG)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
