Browse hierarchy: [Anesthesiology (AN)](/submissions/AN) → [Subpart F — Therapeutic Devices](/submissions/AN/subpart-f%E2%80%94therapeutic-devices) → [21 CFR 868.5300](/submissions/AN/subpart-f%E2%80%94therapeutic-devices/868.5300) → CBL — Absorbent, Carbon-Dioxide

# CBL · Absorbent, Carbon-Dioxide

_Anesthesiology · 21 CFR 868.5300 · Class 1_

**Canonical URL:** https://fda.innolitics.com/productcode/CBL

## Overview

- **Product Code:** CBL
- **Device Name:** Absorbent, Carbon-Dioxide
- **Regulation:** [21 CFR 868.5300](/submissions/AN/subpart-f%E2%80%94therapeutic-devices/868.5300)
- **Device Class:** 1
- **Review Panel:** [Anesthesiology](/submissions/AN)

## Identification

A carbon dioxide absorbent is a device intended for medical purposes that consists of an absorbent material (e.g., soda lime) that is intended to remove carbon dioxide from the gases in the breathing circuit.

## Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 868.9.

## Recent Cleared Devices (5 of 5)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K921803](/device/K921803.md) | SOFNOLIME CARBON DIOXIDE ABSORBENT | Molecular Products , Ltd. | Oct 15, 1992 | SESE |
| [K897171](/device/K897171.md) | DISPOSABLE CO2 ABSORBER/E | Gibeck, Inc. | Mar 13, 1990 | SESE |
| [K860147](/device/K860147.md) | CARBON DIOXIDE ABSORBENTS | Dentsply Intl. | Feb 28, 1986 | SESE |
| [K853571](/device/K853571.md) | MEDIPART SODA LIME MP-3522 | Medipart Jerry Alexander | Oct 29, 1985 | SESE |
| [K811260](/device/K811260.md) | BARALYME CO2 ABSORBENT | Allied Healthcare Products, Inc. | May 27, 1981 | SESE |

## Top Applicants

- Allied Healthcare Products, Inc. — 1 clearance
- Dentsply Intl. — 1 clearance
- Gibeck, Inc. — 1 clearance
- Medipart Jerry Alexander — 1 clearance
- Molecular Products , Ltd. — 1 clearance

---

**Source:** [https://fda.innolitics.com/productcode/CBL](https://fda.innolitics.com/productcode/CBL)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
