← Product Code [HWC](/productcode/HWC) · K992396

# BIORCI SCREW (K992396)

_Smith & Nephew Endoscopy, Inc. · HWC · Jan 12, 2000 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K992396

## Device Facts

- **Applicant:** Smith & Nephew Endoscopy, Inc.
- **Product Code:** [HWC](/productcode/HWC.md)
- **Decision Date:** Jan 12, 2000
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3040
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The BioRCI Screw is used for fixation of bone-tendon-bone or soft tissue grafts during Anterior and/or Posterior Cruciate Ligament (ACL/PCL) reconstruction.

## Device Story

BioRCI Screw is a bone fixation device used in orthopedic surgery; specifically for securing bone-tendon-bone or soft-tissue grafts during ACL/PCL reconstruction. Constructed from polylactic acid (PLA); device is provided in diameters of 7-10 mm and lengths of 25-35 mm. It is a sterile, single-use implant. The screw functions by providing mechanical fixation of the graft to the bone. It is intended for use by surgeons in a clinical/OR setting. The device is substantially equivalent to existing interference screws, sharing similar design, material, and intended use. Benefits include secure graft fixation during ligament reconstruction procedures.

## Clinical Evidence

Bench testing only. Performance testing compared the BioRCI Screw against the RCI Fixation Screw; results are documented in the submission.

## Technological Characteristics

Material: Polylactic acid (PLA). Dimensions: 7-10 mm diameter, 25-35 mm length. Sterilization: Ethylene Oxide. Form factor: Bone fixation screw. Single-use, sterile implant.

## Regulatory Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- RCI Fixation Screws ([K980841](/device/K980841.md))
- Bioabsorbable Interference Screw ([K984320](/device/K984320.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

# 'JAN 1 2 2000

# 510(K) SUMMARY

This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFFR §807.92.

The assigned 510(k) number is :

K992396

This summary was prepared on July 16, 1999

### A. Submitter

Smith & Nephew, Inc., Endoscopy Division 130 Forbes Boulevard Mansfield, MA 02048

# B. Company Contact

Demetrios Tsakonas Clinical/Regulatory Specialist

# C. Device Name

Trade Name: BioRCI Screw Common Name: Screw, Fixation, Bone, Orthopedics Classification Name: Screw: 87HWC

# D. Predicate/Legally Marketed Devices

RCI Fixation Screws Smith & Nephew, Inc. (K980841, 5/20/98) Endoscopy Division 130 Forbes Boulevard Mansfield, MA 02048

Bioabsorbable Interference Screw Smith & Nephew, Inc (K984320, 1/20/99) Endoscopy Division 130 Forbes Boulevard Mansfield, MA 020487

{1}------------------------------------------------

# E. Device Description

The BioRCI Screw is a screw that has a range of diameters from 7 to 10 mm and a length that ranges from 25 mm to 35 mm. The RCI Fixation Interference Screw is provided in a range of diameters from 7 to 9 mm and a range of lengths from 25 to 50 mm. The Bioabsorbable Interference Screw is provided in a range of diameters from 7 to 9 mm and a length that ranges from 20 mm to 30 mm. The material of construction for both the BioRCI and the Bioabsorbable Interference screws is polylactic acid.

#### Performance F.

The BioRCI Screw has been tested against the RCI Fixation Screw. Both screws had results that are recorded in the test results located in attachment one.

## G. Intended Use

The BioRCI Screw has the same intended use as both the RCI Fixation Screw and the Smith & Nephew Bioabsorbable Interference screws. The RCI Fixation screw is used for fixation of bone-tendon-bone grafts or softtissue grafts during Anterior/Posterior Cruciate Ligament (ACL/PCL) reconstruction. The Smith & Nephew Bioabsorbable Interference is used for fixation of bone-tendon-bone grafts or soft-tissue grafts during Anterior/Posterior Cruciate Ligament (ACL/PCL) reconstruction.

# H. Substantial Equivalence

The BioRCI Screw , RCI Fixation Screw, and the Bioabsorbable Interference Screw have similar designs. These screws are used in fixating grafts to bone. The material for the Bioabsorbable Interference Screws and the BioRCI screws are the same and the screws have similar dimensions.

Risks to health have been addressed through the specified materials, processing controls, quality assurance, and compliance to the Medical Device Good Manufacturing Practices regulations.

{2}------------------------------------------------

A summary comparison of the characteristics of the BioRCI Screw and the substantially equivalent devices is presented in the

| Attribute     | Current Product                                                           | Substantially Equivalent Product                                          | Substantially Equivalent Product                                          |
|---------------|---------------------------------------------------------------------------|---------------------------------------------------------------------------|---------------------------------------------------------------------------|
| Indication    | BioRCI Screw                                                              | RCI Fixation Screw                                                        | Smith & Nephew Bioabsorbable Interference Screw                           |
|               | Bone-Tendon-Bone or Soft Tissue Graft Fixation for ACL/PCL Reconstruction | Bone-Tendon-Bone or Soft Tissue Graft Fixation for ACL/PCL Reconstruction | Bone-Tendon-Bone or Soft Tissue Graft Fixation for ACL/PCL Reconstruction |
| Dimensions    | Diameter: 7 - 10 mm<br>Length: 25 - 35 mm                                 | Diameter: 7 - 9 mm<br>Length: 25 - 50 mm                                  | Diameter: 7 - 9 mm<br>Length: 20 - 30 mm                                  |
| Material      | PLA                                                                       | PLA                                                                       | PLA                                                                       |
| Sterilization | Ethylene Oxide                                                            | Ethylene Oxide                                                            | Ethylene Oxide                                                            |
| Labeling      | Sterile, Single Use Only                                                  | Sterile, Single Use Only                                                  | Sterile, Single Use Only                                                  |

Applicant

Bernice Jackson

Date

రా

9

BioRCI Screw 510(k)

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized bird-like symbol, composed of three curved lines that resemble wings or feathers. The symbol is enclosed within a circular border, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the upper half of the circle.

Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

JAN 1 2 2000

Mr. Demetrios Tsakonas Clinical/Regulatory Specialist Smith & Nephew, Inc. Endoscopy Division 130 Forbes Boulevard Mansfield, Massachusetts 02048

Re: K992396

> Trade Name: BioRCI Screw Regulatory Class: II Product Code: HWC Dated: October 19, 1999 Received: October 20, 1999

Dear Mr. Tsakonas:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (OS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to

{4}------------------------------------------------

Page 2 – Mr. Dcmetrios Tsakonas

If you desire specific advice for your device on our labeling regulation (21 CFF) Part 801 and additionally 809.10 for im viro diagnostic devices), please contact the Office of Compliance at additionally 809.10 for in Vitto diagnostions on the promotion and advertising of your device, (301) 394-4595. Addinonally, for questions of the p-4639. Also, please note the regulation please contact the Office or Comphance at (301) stuffication" (21 CFR 807.97). Other general entitled, "Misoranding by recreace to premation in a may be obtains of Small
information on your responsibilities under the Act may be obtained from the 1907 of its information on your responsibilities ander the receins, 63-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".

Sincerely yours,

Yundell Jager

-52 -- James E. Dillard III Acting Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

510 (k) Number (If Known):

510 (k) Number (If Known): K992396

Device Name: BioRCI Screw

Intended Use:

The BioRCI Screw is used for fixation of bone-tendon-bone or soft tissue grafts during Anterior and/or Posterior Cruciate Ligament (ACL/PCL) reconstruction.

Indications:

(Per 21 CFR 801.109)

- The BioRCI Screw is used for fixation of bone-tendon-bone or soft-tissue . grafts during Anterior and/or Posterior Cruciate Ligament (ACL/PCL) reconstruction.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Sign-Off)
of General Restorative Devices
(k) Number K-99 2396

Prescription Use X or Over-The-Counter Use

---

**Source:** [https://fda.innolitics.com/device/K992396](https://fda.innolitics.com/device/K992396)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
