K990593 · Deschutes Medical Products, Inc. · HHW · May 24, 1999 · Obstetrics/Gynecology
Device Facts
Record ID
K990593
Device Name
PELVX INCONTINENCE DISH, MODEL 301-306
Applicant
Deschutes Medical Products, Inc.
Product Code
HHW · Obstetrics/Gynecology
Decision Date
May 24, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 884.3575
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The PelvX Incontinence Dish Vaginal Pessary is intended for treatment of stress urinary incontinence combined with a mild 1st or 2nd degree uterine prolapse and/or a mild cystocele.
Device Story
PelvX Incontinence Dish is a reusable vaginal pessary; constructed of medical-grade silicone; dish-shaped to support cervical and bladder areas. Features a bulbous portion on the circumference to support and elevate the bladder neck, improving urethral sphincter control. Device is fitted by medical personnel; requires regular clinical visits for monitoring and fit checks. Patient removes device before coitus; cleans with soap and water. Intended to treat stress urinary incontinence and mild prolapse/cystocele by providing mechanical support to pelvic structures.
Clinical Evidence
Bench testing only. Biocompatibility testing performed by NamSA included acute systemic toxicity, cytotoxicity, muscle implantation (1, 4, and 12 weeks), ISO sensitization, pyrogenicity, and vaginal irritation (14 days). Testing followed ISO-10993 requirements for mucosal membrane contact devices.
Technological Characteristics
Material: medical grade silicone. Form factor: dish-shaped with bulbous support and drainage holes. Dimensions: 6 sizes ranging from 2.25" to 3.5". Sterilization: supplied clean, non-sterile. Reusable. Mechanical support principle.
Indications for Use
Indicated for patients with stress urinary incontinence combined with mild 1st or 2nd degree uterine prolapse and/or mild cystocele. Contraindicated in patients with pelvic infections, lacerations, endometriosis, pregnancy, or non-compliant patients.
Regulatory Classification
Identification
A vaginal pessary is a removable structure placed in the vagina to support the pelvic organs and is used to treat conditions such as uterine prolapse (falling down of uterus), uterine retroposition (backward displacement), or gynecologic hernia.
{1}------------------------------------------------
PelvX 510(k)
02/22/99
K90593
MAY 2 4 1999
# 510(k) SUMMARY PelvX Incontinence Dish
DesChutes Medical Products, Inc. 1011 SW Emkay Drive, Suite 104 Bend, OR 97702 Date Prepared: 2/19/99
## 1. CONTACT PERSON
| Denise Bestwick |
|-----------------|
|-----------------|
| Phone | : (541) 385-0350 |
|-------|------------------|
| Fax | : (541) 382-2079 |
#### 2. NAME OF THE MEDICAL DEVICE
| Classification name | : Vaginal Pessary |
|---------------------|---------------------------|
| Common/usual name | : Vaginal Pessary |
| Proprietary name | : PelvX Incontinence Dish |
#### 3. DEVICE CLASSIFICATION
PelvX Incontinence Dish Vaginal Pessary is classified by the FDA under the heading of Vaginal Pessary (21 CFR Section 884.3575) as a Class II device with Product Code: 85HHW.
#### STATEMENT OF SUBSTANTIAL EQUIVALENCE 4.
PelvX Incontinence Dish Vaginal Pessary is substantially equivalent to the Milex Incontinence Dish pessary, manufactured by Milex Products, Inc., Chicago, IL 60631.
A comparison of the PelvX Devices versus the Milex Devices is presented in Tables 1 and 2.
### 5. INTENDED USE
The PelvX Incontinence Dish Vaginal Pessary is intended for treatment of stress urinary incontinence combined with a mild 1st or 2nd degree uterine prolapse and/or a mild cystocele.
#### DESCRIPTION OF DEVICE 6.
The PelvX Incontinence Dish Vaginal Pessary is a pessary intended for the treatment of stress urinary incontinence. It is made of medical grade silicone and is shaped like a dish to surround and support the cervical area and bladder areas. Holes in the dish allow drainage of vaginal fluids. It features a bulbous portion at one location on its circumference designed to support and elevate the bladder neck, thereby providing improved urethral sphincter control. Figure 1 shows a diagram of the PelvX Incontinence Dish.
{2}------------------------------------------------
### 7. SUBSTANTIAL EQUIVALENCE COMPARISON
Tables 1 and 2 demonstrate the regulatory classifications and features of the DesChutes Incontinence Ring compared to the Milex Incontinence Ring.
The common and classification names for these products are identical. In addition, both of these devices are prescription devices.
These vaginal pessaries are reusable devices which must be fitted, checked for continuing fit, and monitored for developing problems by medical personnel. The DesChutes and Milex Dishes have identical intended uses. The contraindications for their use are also the same. The pessaries are supplied clean but not sterile. Cleaning procedures are also the same. Both devices come in a variety of sizes for fitting.
There are several differences between the DesChutes and Milex products. First, DesChutes explicitly states that these are single patient devices while Milex is silent on this point. Second, DesChutes adds a precaution that the pessary should be removed before coitus. Finally the pessaries are packaged differently which does not affect the intended use or performance of the product.
| Category | DesChutes Medical Products<br>PelvX Incontinence Dish | Milex Products<br>Incontinence Dish with<br>Support |
|-----------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------|
| Common or usual name | vaginal pessary | vaginal pessary |
| Classification name | 884.3575 Vaginal pessary | 884.3575 Vaginal pessary |
| Product Code | 85HHW | 85HHW |
| Prescription device | Yes | Yes |
| Feature | DesChutes Medical Products<br>PelvX Incontinence Dish | Milex Products<br>Incontinence Dish<br>with Support |
| Intended Use | treatment of stress urinary incontinence combined with 1st or 2nd degree prolapse and/or a mild cystocele | stress urinary incontinence coupled with a mild 1st or 2nd degree prolapse and/or a mild cystocele |
| Single patient device | yes | implied but not specifically stated |
| Single use or reusable | reusable | reusable |
| Must be initially fitted by<br>medical personnel | yes | yes |
| Requires regular visits to<br>medical personnel for<br>checking | yes | yes |
| Contraindications | 1) pelvic infections or<br>lacerations<br>2) non-compliant patients<br>3) endometriosis<br>4) pregnancy | 1) pelvic infections or<br>lacerations<br>2) non-compliant patients<br>3) endometriosis<br>4) pregnancy |
| Cautions | 1) pessary should be removed before coitus | |
| Sterilization status | clean, but not sterile | clean, but not sterile |
| Foldable | yes | yes |
| Maintenance | clean with warm water and soap when removed | clean with water and mild soap when removed |
| Material<br>Outer | medical grade silicone | medical grade silicone |
| Color additives | yes | yes |
| Number of models | 6 | 6 |
| Sizes | 2.25", 2.5", 2.75", 3", 3.25",<br>3.5" | 55mm, 60mm, 65mm, 70mm,<br>75mm, 80mm, 85mm |
| Instructions | physician and patient<br>instructions | physician/nurse and patient<br>instructions |
| Packaging | plastic bag inside paperboard box with label | plastic clamshell with instructions for use visible |
### Table 1-Comparison of Regulatory Classifications
{3}------------------------------------------------
## Table 2 -Comparison of Device Features
#### 8. SUMMARY OF SAFETY TESTING
The DesChutes PelvX Incontinence Dish is made of a known medical grade silicone. Extensive testing of this silicone was performed for DesChutes Medical Products by NamSA. The following tests were performed:
{4}------------------------------------------------
Acute Systemic Toxicity Cytotoxicity Muscle Implantation (1 week) Muscle Implantation (4 weeks) Muscle Implantation (12 weeks) ISO Sensitization Study Pyrogenicity Vaginal Irritation (14 days)
The material used is the same as for the DesChutes Donut Pessary (510(k) #974117). This testing regime was compared to requirements in "General Purpose Memorandum G95-1 Use of International Standard ISO-10993" for devices in contact with mucosal membranes for between 24 hours and 30 days. The test results support the position that this material is substantially equivalent to the other materials used for similar purposes.
{5}------------------------------------------------
Image /page/4/Figure/0 description: This image shows a technical drawing of a pessary incontinence dish. The drawing includes multiple views of the dish, with dimensions labeled such as 1.100, 2.750, 1.000, 0.651, and 1.600. The scale of the drawing is 1:1, and notes indicate the finish is DHE C-3 and parts should be furnished clean and dry. The drawing also includes a part number 110303 and specifies that dimensions are in inches.
### DesChutes Medical Products, Inc. PelvX 510(k) FIGURE 1. DIAGRAM OF PELVX INCONTINENCE DISH
02/22/99
{6}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States of America. The seal features a stylized eagle with its wings spread, symbolizing protection and vigilance. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle.
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAY 2 4 1999
Ms. Denise Bestwick Director, Quality Assurance and Regulatory Affairs DesChutes Medical Products, Inc. 1011 S.W. Emkay Drive, Suite 104 Bend, OR 97702
Re: K990593 PelvX Incontinence Dish Vaginal Pessary Dated: February 22, 1999 Received: February 24,1999 Regulatory Class: II 21 CFR §884.3575/Procode: 85 HHW
Dear Ms. Bestwick:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class III (Premarket Approval), it may be subject to such additional controls. Existing major requlations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".
Sincerely yours,
CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
### Statement of Indications for Use
510(K) Number (if known): 长990593
Device name: PelvX Incontinence Dish Vaginal Pessary
Indications for Use:
.. -
The PelvX Incontinence Dish Vaginal Pessary is a vaginal pessary intended for the treatment of stress urinary incontinence combined with mild 1st or 2nd degree uterine prolapse and/or a mild cystocele.
(Please do not write below this line) 营款电信维修在发展或者的优质量是是是是最高品质量和用品质量和产品 Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) (Division of Reproductive, Abdominal, ENT, and Radiological Devices 510(k) Number Prescription Use_ OR Over-The-Counter Use _
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.