← Product Code [HIN](/productcode/HIN) · K990147

# BIPOLAR FORCEPS, KLEPPINGER INSERT, MODEL #'S 8393.741,8393.771,8394.741,8394.771 (K990147)

_Richard Wolf Medical Instruments Corp. · HIN · Apr 16, 1999 · Obstetrics/Gynecology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K990147

## Device Facts

- **Applicant:** Richard Wolf Medical Instruments Corp.
- **Product Code:** [HIN](/productcode/HIN.md)
- **Decision Date:** Apr 16, 1999
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 884.4150
- **Device Class:** Class 2
- **Review Panel:** Obstetrics/Gynecology
- **Attributes:** Therapeutic

## Indications for Use

The coagulation of tubes, tissue coagulation and vascular coagulation, and to stop bleedings under endoscopic vision, including coagulation of the fallopian tube and the mesoalpinx for female sterilization.

## Device Story

Modular bipolar forceps used for tissue/vascular coagulation and hemostasis during endoscopic procedures. Device features jaws for grasping/holding tissue and an integrated cleaning port for hygiene. Operated by surgeons in clinical/endoscopic settings. Provides precise axial holding and coagulation under endoscopic visualization. Benefits include improved site access and hygiene without requiring additional instruments. Device utilizes electrical energy for coagulation; design incorporates durable coated insulation on electrodes.

## Clinical Evidence

No clinical data performed. Bench testing conducted per ANSI/AAMI HF18 and IEC601-2-2 standards for high-frequency devices. Biocompatibility testing performed on new materials.

## Technological Characteristics

Modular bipolar forceps; electrodes with durable coated insulation; integrated cleaning port. Energy source: high-frequency electrical. Standards: ANSI/AAMI HF18, IEC601-2-2. Biocompatible materials.

## Regulatory Identification

A bipolar endoscopic coagulator-cutter is a device used to perform female sterilization and other operative procedures under endoscopic observation. It destroys tissue with high temperatures by directing a high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and electrical cables.

## Special Controls

*Classification.* Class II. The special controls for this device are:(1) FDA's:
(i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ”
(ii) “510(k) Sterility Review Guidance 2/12/90 (K-90),” and
(iii) “Guidance (‘Guidelines’) for Evaluation of Laproscopic Bipolar and Thermal Coagulators (and Accessories),”
(2) International Electrotechnical Commission's IEC 60601-1-AM2 (1995-03), Amendment 2, “Medical Electrical Equipment—Part 1: General Requirements for Safety,”
(3) American National Standards Institute/American Association for Medical Instrumentation's HF-18, 1993, “Electrosurgical Devices,”
(4) Labeling:
(i) Indication: For female tubal sterilization, and
(ii) Instructions for use:
(A) Destroy at least 2 centimeters of the fallopian tubes,
(B) Use a cut or undampened sinusoidal waveform,
(C) Use a minimum power of 25 watts, and
(D) For devices with ammeters: continue electrode activation for 5 seconds after the visual endpoint (tissue blanching) is reached or current flow ceases indicating adequate tissue destruction.

## Predicate Devices

- Kleppinger bipolar forceps 8383.21, 8384.21 (pre-enact.)
- Modular Bipolar Forcep Sets 8390/91/93/94 ([K981321](/device/K981321.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

4/16/99

1

■

353 Corporate Woods Vernon I lills, Illinois 6006 I Phone: 847.913.4143 Fax: \$47.943.4488

RICHARD W MEDICAL INSTRUMENTS CORPORA

Image /page/0/Picture/9 description: The image shows a black square with a white drawing inside. The drawing appears to be a stylized representation of an animal, possibly a dog or wolf, standing on its hind legs. The animal has a long neck and a pointed head, and it is wearing some sort of garment or harness around its body.

# 510(k) Summary of Safety and Effectiveness

| Submitter:                             | Date of Preparation:                                  |          |                    |
|----------------------------------------|-------------------------------------------------------|----------|--------------------|
| Company / Institution name:            | January 13, 1999                                      |          |                    |
| RICHARD WOLF MEDICAL INSTRUMENTS CORP. | FDA establishment registration number:                |          |                    |
| Division name (if applicable):         | 1418479                                               |          |                    |
| N.A.                                   | Phone number (include area code):                     |          |                    |
|                                        | (847) 913-1113                                        |          |                    |
| Street address:                        | FAX number (include area code):                       |          |                    |
| 353 Corporate Woods Parkway            | (847) 913-0924                                        |          |                    |
| City:                                  | State/Province:                                       | Country: | ZIP / Postal Code: |
| Vernon Hills                           | Illinois                                              | USA      | 60061              |
| Contact name:                          |                                                       |          |                    |
| Mr. Robert L. Casarsa                  |                                                       |          |                    |
| Contact title:                         |                                                       |          |                    |
| Quality Assurance Manager              |                                                       |          |                    |
| Product Information:                   |                                                       |          |                    |
| Trade name:                            | Model number:                                         |          |                    |
| Bipolar forcep set (modular)           | 8393.741, 8393.771, 8394.741, 8394.771                |          |                    |
| Common name:                           | Classification name:                                  |          |                    |
| Modular Bipolar forceps                | Coagulator-Cutter, Endoscopic,<br>Bipolar Accessories |          |                    |

Information on devices to which substantial equivalence is claimed:

| 510(k) Number | Trade or proprietary or model name            | Manufacturer                       |
|---------------|-----------------------------------------------|------------------------------------|
| 1 pre-enact.  | 1 Kleppinger bipolar forceps 8383.21, 8384.21 | 1 Richard Wolf GmbH                |
| 2 K981321     | 2 Modular Bipolar Forcep Sets 8390/91/93/94   | 2 Richard Wolf Medical Instruments |

### 1.0 Description

The modular bipolar forcep set provides precise grasping and axial holding placement of the jaws, performs thorough hygiene, and site irrigation can be achieved without using additional instruments.

{1}------------------------------------------------

Image /page/1/Picture/3 description: The image contains a single Chinese character, '得', in a bold, sans-serif font. The character is black against a white background. The character appears to be centered in the image.

#### 2.0 Intended Use

The coagulation of tubes, tissue coagulation and vascular coagulation, and to stop bleedings under endoscopic vision, including coagulation of the fallopian tube and the mesoalpinx for female sterilization.

#### 3.0 Technological Characteristics

There are no significant technological characteristic changes to the new devices compared to the pre-enactment devices. The insulation of the electrodes is changed to a more durable coated material. A cleaning port is added. The instruments are identical to those cleared by K981321.

#### 4.0 Substantial Equivalence

The submitted devices pose the same type of questions about safety or effectiveness as the compared devices. The new technological characteristics have not diminished safety or effectiveness. The submitted devices are substantially equivalent to existing pre-enactment devices sold by Richard Wolf. In addition, the submitted devices are substantially equivalent to devices sold by various competitors.

#### 5.0 Performance Data

No known FDA performance standard exists.

The bipolar forceps were tested to meet the appropriate sections of the ANSV AAMI standard on high frequency devices HF18 and IEC601-2-2, Device materials tests were performed to assure biocompatibility of the new material. The tests indicated that no irrigation would occur.

#### 6.0 Clinical Tests

No special clinical tests performed.

#### 7.0 Conclusions Drawn

These devices are designed and tested to guarantee the safety and effectiveness, when used according to the instructions manual.

By: Robert L. Pearson

Date: Apr 16, 99

Robert L. Casarsa Quality Assurance Manager

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three lines forming its body and wings. The eagle is encircled by the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA". The text is arranged in a circular fashion around the eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

APR 16 1999

Mr. Robert L. Casarsa Quality Assurance Manager RICHARD WOLF MEDICAL INSTRUMENTS CORP. 353 Corporate Woods Parkway Vernon Hills, IL 60061

Re: K990147 Modular Bipolar Forcep Set, Kleppinger Principle Dated: January 13, 1999 Received: January 19, 1999 Regulatory Class: III 21 CFR 884.4150/Procode: 85 HIN

Dear Mr. Casarsa:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".

Sincerely yours.

CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

## * (*) : 10) :

510(k) Number (if known):

Modular Bipolar Forcep Set. Kleppinger Principle Device Name:__________________________________________________________________________________________________________________________________________________________________

### Intended Use:

The coagulation of tubes, tissue coagulation and vasculation, and to stop bleedings under endoscopic vision, including coagulation of the fallopian tube and the mesoalpinx for female sterilization.

(IT EASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOXITIER PAGE IF NEEDED)

Prescription Use
Per 21 CFR 801.109

---

**(Division Sign-Off)**

and Radiological Devices

510(k) Number_

Division of Reproductive, Abdominal, ENT,

()R

Over-The Counter_

5 - 1

---

**Source:** [https://fda.innolitics.com/device/K990147](https://fda.innolitics.com/device/K990147)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
