K984196 · Ssgi Prowess Systems · MUJ · Dec 11, 1998 · Radiology
Device Facts
Record ID
K984196
Device Name
MODIFICATION TO PROWESS PRO-SIM
Applicant
Ssgi Prowess Systems
Product Code
MUJ · Radiology
Decision Date
Dec 11, 1998
Decision
SESE
Submission Type
Special
Regulation
21 CFR 892.5050
Device Class
Class 2
Attributes
Software as a Medical Device
Indications for Use
The Prowess Pro-Sim treatment planning system is used to plan patient treatment for radiation therapy.
Device Story
Prowess Pro-Sim is a radiation therapy treatment planning system (TPS) used by clinicians to design treatment plans for cancer patients. The system ingests patient CT images (DICOM 3.0) via network. It creates a patient model, defines tumor volumes via auto-contouring (Hounsfield thresholding) or manual editing, and simulates beam geometry (photon/electron). The system calculates dose distributions using established algorithms (Effective Path Length or Batho Power Law models). Outputs include 2D/3D dose distribution visualizations, DRRs, and machine settings for treatment delivery. It operates on Windows NT workstations in a clinical environment. By integrating dose calculation directly into the simulation software, it eliminates the need to export data to external systems, allowing immediate assessment of beam/plan changes on patient dosimetry. This facilitates optimized treatment planning and improved clinical decision-making for radiation therapy delivery.
Clinical Evidence
No clinical data provided. Substantial equivalence is based on bench testing and comparison of software features and calculation algorithms against the predicate device.
Technological Characteristics
Software-based radiation therapy treatment planning system. Runs on Pentium Pro/II workstations with Windows NT. Supports DICOM 3.0, TCP/IP networking, and 24-bit True Color display. Features include auto-contouring (Hounsfield thresholding), 3D visualization, and dose calculation models (Effective Path Length, Batho Power Law).
Indications for Use
Indicated for cancer patients undergoing therapeutic radiation treatment, including Brachytherapy and External Beam (photon or electron) therapy, to prepare individual treatment plans.
Regulatory Classification
Identification
A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.
{1}------------------------------------------------
K984196
DEC 1 1 1998
Image /page/0/Picture/2 description: The image shows a logo with the letters "SSGI" below a triangular shape. The triangle has a stylized "S" shape cut out of it, and the upper left corner of the triangle is filled with a pixelated or fragmented pattern. A horizontal line is located under the letters "SSGI".
Prowess Systems 1370 Ridgewood Dr., Ste. 20 Chico, California 95973 Tel: (530) 898-0660 Fax: (530) 342-8966
# 510(k) Summary of Safety and Effectiveness
- 1. Submitter:
SSGI 1370 Ridgewood Drive Suite 20 Chico, CA 95973
Contact: Robert J. Morton Director, Regulatory Affairs and Quality Assurance
Prepared: November 16, 1998
- Prowess Pro-Sim 2. Device Name: Radiation Therapy Treatment Planning System
- SSGI Prowess Pro-Sim, K980379 3. Predicate Device:
- 4. Description: The Prowess treatment-planning product is a series of independent software programs used to plan a course of radiation therapy. The treatment plan includes an estimated dose distribution for a patient. The dose is calculated by applying known and tested algorithms. Measured treatment machine data combined with geometric and tissue information, for a particular patient, are processed by the algorithm into a dose distribution.
The Prowess Treatment Planning System (TPS) is separated into three major components:
- 1. Incorporating patient data into a patient model.
- 2. Creating treatment plans for each set of patient data.
- Calculating the treatment plans. 3.
Pro-Sim TPS has all of the features of Pro-Sim VPS with the dose calculation capability of P3000. In this program the dose distribution can be shown in the 2D and 3D views.
- 5. Intended Use: The Prowess Pro-Sim treatment planning system is used to plan patient treatment for radiation therapy.
- Technological Characteristics: See attached Comparison Table. 6.
Image /page/0/Picture/19 description: The image shows the logo and contact information for Prowess Systems. The logo features a triangle with a stylized design inside, accompanied by the letters "SSGI" underneath. The contact information includes the address "1370 Ridgewood Dr., Ste. 20, Chico, California 95973", along with the phone number "(530) 898-0660" and fax number "(530) 342-8966".
"Serving our customers' needs"
{2}------------------------------------------------
# Tab 15 Comparison to Unmodified Device
| Prowess Treatment Planning System | Prowess<br>Pro-Sim<br>Predicate<br>K0980379<br>Device | Prowess<br>Pro-Sim TP-<br>Modified<br>Device |
|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------|----------------------------------------------|
| Basic Features<br>Pro-Sim VPS has the ability to receive information from any<br>manufacturer's CT scanner with DICOM 3.0 format on a network system.<br>The Pro-Sim VPS computerized simulation process involves creation of a<br>digitally reconstructed radiograph (DRR) in any plane desired. This appears<br>on the computer screen for modification. The tumor volume is defined by<br>adding multiple interior structure outlines to the transverse slices. In the<br>beam's eye view, custom blocks and multileaf collimator blocking are<br>accurately simulated by Pro-Sim VPS. These are superimposed on the<br>grayscale DRR presented on the screen. Advanced tools for 3D<br>visualization are transverse planes and wireframe contours surrounding 3D<br>renderings of internal tumors and structures. | X | X |
| As the computer simulation is performed, the actual dose generated from<br>the beams can be displayed in Pro-Sim TPS, change the beam or plan and<br>watch the effect on the patient dosimetry, immediately. | | X |
| Basic System Design<br>• DICOM 3 compliant.<br>• Multilingual product design.<br>• Screen layout organized for rapid and consistent image display. Screen<br>includes four display windows, a toolbar area, window and level graphic<br>display, menu area and common function areas. All windows are active<br>and have independent control. | X<br>X<br>X | X<br>X<br>X |
| Image Acquisition<br>• DICOM 3 compliant Pro-Sim will accept CT images from any DICOM 3<br>image source. | X | X |
| • Ability to recall patients stored on any network station.<br>• Supports local area networks, wide area networks, or a distributed<br>network through TCP/IP networking. | X<br>X | X<br>X |
| • At least 100 CT slices per study accepted. | X | X |
| Prowess Treatment Planning System | Prowess<br>Predicate<br>Device | Prowess<br>Modified<br>Device |
| <b>Image Processing and Anatomical Modeling</b> | | |
| • Rapid auto contouring includes multiple organ contouring using a<br>Hounsfield number threshold technique. | X | X |
| • Easy entry of field shapes and calculation points. | X | X |
| • External and internal autocontouring. Batch autocontouring for<br>multiplanar entry. | X | X |
| • Easy manual contouring and editing. | X | X |
| • Full mouse support. | X | X |
| • Easy to add margins on all volumes. | X | X |
| • Entry of calculation points for reference. | X | X |
| • Multiple calculation points available for a single field. | X | X |
| • Entry of fiducial points or isocenter marking to register patient anatomy. | X | X |
| <b>Full Three Dimensional Visualization of Treatment Setup</b> | | |
| • The treatment unit and patient anatomy can be visualized in three<br>dimensions from any point in the treatment room. | X | X |
| • Direction of view can be dynamically moved in real time for full<br>visualization of machine and patient. | X | X |
| • Anatomical features can be turned on and off easily. | X | X |
| • Full Zoom and Pan in each window. | X | X |
| • Turn on and off each contour display. | X | X |
| • Choose from a set of predefined beam configurations (e.g., Four Field,<br>AP/PA, etc...) | X | X |
| • Supports beam configured for any 'brand' accelerator gantry and/or table<br>orientation. | X | X |
| • Full 3-D patient and beam geometry. | X | X |
| • Independent jaws fully supported. | X | X |
| • Full couch, collimator and gantry rotation supported. | X | X |
| • MLC supported. | X | X |
| <b>External Beam Dose Calculations</b> | | |
| • Photon and electron beams can be combined in a single plane. | X | X |
| • Photon calculation makes extensive use of measured TMR/TPR data. Two<br>heterogeneity models available: | X | X |
| Effective Path Length | X | X |
| Batho Power Law | X | X |
| • Bolus, compensators, blocks, and/or wedges may be mixed freely. | X | X |
| • CT pixel/density correction available. | X | X |
| Prowess Treatment Planning System | Prowess<br>Predicate<br>Device | Prowess<br>Modified<br>Device |
| • At least 20 active beams per plan may be entered. They may be fixed or<br>rotational beams. | X | X |
| • Necessary to export for dose calculations | X | |
| • 2D scatter calculations available. | X | X |
| • Calculation matrix size up to 16,384 per slice. | X | X |
| • Calculation of machine setting for each field. | X | X |
| • Non-coplanar beam calculations. | | X |
| • 3D dose display. | | X |
| Hardcopy | | |
| • Scaleable color PostScript™ or HPGL hardcopy of CT images with color<br>isodose curves. | X | X |
| • Pro-Sim hardcopy produces full color or black and white output on paper<br>or film. | X | X |
| • Pro-Sim supports all printers supported by Windows NT. | X | X |
| • Full color hardcopy available. | X | X |
| • Dye sublimation printers (optional). | X | X |
| Recommended Minimum Hardware Configuration | | |
| • Pentium® Pro or Pentium II workstation. | X | X |
| • Windows NT server or workstation operating system. | X | X |
| • 17" monitor. | X | X |
| • Screen resolution 1280 x 1024 pixels. | X | X |
| • 24-bit True Color display. CT or MRI images displayed using full 256<br>gray levels. | X | X |
| • Windows NT networking allowing multiple workstations for simultaneous<br>simulation by physicians, physicists and dosimetrists. | X | X |
| Export / Import Features | | |
| • All anatomical data including CT images can be exported to the Prowess<br>3000 RTP System using APEXTM | X | X |
| • All anatomical contouring data can be exported to the Prowess 3000 RTP<br>system. | X | X |
| • Beam data generated by Pro-Sim can be exported to Prowess 3000 RTP. | X | X |
{3}------------------------------------------------
{4}------------------------------------------------
{5}------------------------------------------------
#### Summary of Differences
Pro-Sim TPS is identical to Pro-Sim VPS, the predicate device with the exception that the dose calculations have been moved from Prowess 3000 into Pro-Sim VPS, creating Pro-Sim TPS. There is no longer a need to export the patient and beam geometry to Prowess 3000 to do the dose calculations. The calculation models are the same for both systems, Prowess 3000 and Pro-Sim TPS.
The comparison shows only two significant features that Pro-Sim TPS can do that the predicate system cannot do. First, Pro-Sim TPS can display the multi-slice dose calculation in 3D (there was no 3D view for dose calculations in the predicate device) and second, Pro-Sim TPS can do full non-coplanar beam calculations. The predicate device could perform dose calculations in all planes but could not combine them at one time due to machine interface limitations.
{6}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the top half of the circle. Inside the circle is an abstract symbol resembling an eagle or bird in flight, composed of three curved lines that suggest feathers or wings.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC 1 1 1998
Robert J. Morton Director. Regulatory Affairs and Quality Assurance Prowess Systems 1370 Ridgewood Dr. Suite 20 Chico, California 95973
Re: K984196
Prowess Pro-Sim (Radiation Therapy Treatment Planning System) Dated: November 19, 1998 Received: November 23, 1998 Regulatory class: II 21 CFR 892.5050/Procode: 90 MUJ
Dear Mr. Morton:
We have reviewed your Section 510/k) notification of intent to market the device referenced above and we have determined the. device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class III (Fremarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (OS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic OS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition. FDA may mobilish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Flectronic Product Radiation Control provisions, or other Federal laws or regulations
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsmaldsmamain.html".
Sincerely yours,
Kilian Yi
Lillian Yin, Ph.D. Director, Division of Reproductive Abdominal, Ear, Nose and Throa and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
## Tab 9
## Indications For Use
510(k) Number (if known):_
Device Name: Prowess Pro-Sim Treatment Planning System
Indications for Use:
Prowess Pro-Sim is a modularly designed radiation therapy treatment planning computer program used to prepare individual treatment plans for cancer patients undergoing therapeutic radiation treatment. The system is utilized to develop treatment plans for Brachytherapy and External Beam (photon or electron) therapy. Completed treatment plans can displayed in 3D prior to treatment.
(PLEASE DO NOT WRITE BELOW THIS LINE)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Vavid A. Seymann
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices 510(k) Number
Prescription Use V (per 21 CFR 801.109)
OR
Over-The-Counter Use_
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.