← Product Code [ERL](/productcode/ERL) · K983050

# PNEUMATIC CUTTER SYSTEM (K983050)

_Surgical Laser Technologies, Inc. · ERL · Nov 25, 1998 · Ear, Nose, Throat · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K983050

## Device Facts

- **Applicant:** Surgical Laser Technologies, Inc.
- **Product Code:** [ERL](/productcode/ERL.md)
- **Decision Date:** Nov 25, 1998
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 874.4250
- **Device Class:** Class 2
- **Review Panel:** Ear, Nose, Throat
- **Attributes:** Therapeutic

## Indications for Use

The SLT Pneumatic Cutter System is indicated for use in Ear Nose and Throat Surgery primarily sinus endoscopy, and orthopedic procedures primarily arthroscopy. The cutter is intended to achieve the removal of tissue, both soft tissue and bone with the appropriate handpiece. It will also provide suction and irrigation to the operative site.

## Device Story

SLT Pneumatic Cutter System; surgical debrider for ENT and orthopedic procedures. Device utilizes disposable cutting blades with integrated irrigation and suction ports. Operates via pneumatic power to cut/remove soft tissue and drill bone; simultaneously suctions debris and bone fragments from operative site. Used by surgeons in clinical settings (OR). Provides alternative to existing debrider instruments; facilitates tissue removal and site clearance during endoscopic/arthroscopic surgery.

## Clinical Evidence

Bench testing only. No clinical data provided.

## Technological Characteristics

Pneumatic-powered surgical cutter; disposable cutting blades with integrated irrigation/suction channels. Designed for soft tissue and bone removal. System includes handpiece and pneumatic control unit.

## Regulatory Identification

An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that is intended to drive various accessories, such as an ear, nose, and throat bur (§ 874.4140), for the controlled incision or removal of bone in the ear, nose, and throat area.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

983050

## 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS

The SLT Pneumatic Cutter System is indicated for use in Ear Nose and Throat Surgery primarily sinus endoscopy, and orthopedic procedures primarily arthroscopy. The cutter is intended to achieve the removal of tissue, both soft tissue and bone with the appropriate handpiece. It will also provide suction and irrigation to the operative site.

Description statements were not relied on to show substantial equivalence to legally marketed devices; instead, performance data from device validation is used. The comparison of intended use and technological features of this device to other legally marketed devices taken together with validation results indicate that this device is substantially equivalent to legally marketed predicate devices with regards to safety, effectiveness and intended use.

The intended use of this device is the same as the intended use of other debrider instruments marketed to provide the same tissue effects. Therefore, all aspect of this device have predicates which are well accepted in the clinical This product simply provides an alternative to those currently community. marketed devices.

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of a human figure with three lines representing the head, body, and legs.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

NOV 25 1998

Ms. Monica Ferrante Regulatory Affairs Surgical Laser Technologies, Inc. 147 Keystone Dr. Montgomeryville, Pennsylvania 18936

Re: K983050 Trade Name: SLT Pneumatic Cutter System Regulatory Class: II Product Code: ERL Dated: September 1, 1998 Received: September 1, 1998

Dear Ms. Ferrante:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

{2}------------------------------------------------

Page 2 - Ms. Monica Ferrante

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".

Sincerely yours,

Celia M. Witten, Ph.D., M.D.
Director

Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows a handwritten string of characters. The string starts with the letter 'k', followed by the numbers '983050'. The characters are written in a cursive style, with the numbers being connected to each other.

## INDICATIONS FOR USE

The SLT Pneumatic Cutter System is intended to cut and remove soft tissue. The primary areas of use are Sinus Endoscopy (ENT) and Arthroscopy (Orthopedic) procedures. The tissue is cut with a disposable cutting blade which has an irrigation and suction port designed into its core. The tissue is automatically suctioned away once cut. The device can also drill bone material and automatically remove the bone dust and fragments through an internal suction port.

This device is a prescription device.

Prescription Use
(Per 21 CFR 801.109)

(Division Sign-Off)
```

510(k) Number K983050

---

**Source:** [https://fda.innolitics.com/device/K983050](https://fda.innolitics.com/device/K983050)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).