UNIVERSAL INSTRUMENT REGISTRATION (UIR) MICROSCOPE MODULE I

K981213 · Radionics, Inc. · HAW · Jul 1, 1998 · Neurology

Device Facts

Record IDK981213
Device NameUNIVERSAL INSTRUMENT REGISTRATION (UIR) MICROSCOPE MODULE I
ApplicantRadionics, Inc.
Product CodeHAW · Neurology
Decision DateJul 1, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.4560
Device ClassClass 2

Indications for Use

The system accessories are indicated for all cranial and spinal surgical procedures covered by the OTS where anatomical Spinal Surgicur procedures is is where a desired target is close to critical structures.

Device Story

Device consists of registration hardware, LED array hardware, and operational software; functions as accessory to Radionics Optical Tracking System (OTS). LED arrays attach to surgical instruments or microscopes; system correlates instrument/microscope position to preoperative patient scan data. Used intraoperatively by surgeons to guide instruments and microscopes to surgical targets. Provides visualization aid; assists in navigating near critical anatomical structures during cranial and spinal procedures.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Modular system comprising registration device, LED array hardware, and operational software. Operates as an accessory to the Radionics Optical Tracking System (OTS). Utilizes LED-based optical tracking for spatial correlation of surgical instruments and microscopes to patient scan data.

Indications for Use

Indicated for patients undergoing cranial and spinal surgical procedures where a target is near critical structures.

Regulatory Classification

Identification

A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ 5.0 510(k) Summary. K981213 ## 510(k) Summary This summary of 510(k) safety and effectiveness information is submitted in accordance with the requirements of the Safe Medical Devices Act of 1990 and 21 C.F.R. § 807.92. 1. The submitter of this premarket notification is: Lisa Misterka Benati Senior Regulatory Engineer Radionics Software Applications, Inc. 22 Terry Avenue Burlington, MA01803 Tel: (781) 272 - 1233 Fax: (781) 272 - 2428 This summary was prepared on April 1, 1998. 2. The names of these devices are the Radionics Universal Instrument Registration and Microscope Module I accessories for use with Radionics Optical Tracking System (OTS). The common name is Intraoperative Guidance Device, and its classification name is Stereotaxic instrument (accessory) 3. The above modular product groups are substantially equivalent to the Zeiss Surgical Microscope Navigator (SMN) and Surgical Tool Navigator (STN) modular product groups manufactured by Carl Zeiss, Inc 4. The above modular product groups consist of a registration device, LED array hardware, and operational software. When coupled with the OTS workstation, the devices allow for preoperative and operative planning of surgical procedures through workstation images. 5. The accessories are intended as a visualization aid to surgery. When fitted to a surgical instrument, the LED array hardware allows the surgeon to correlate the instrument location to the patient scan data. Likewise, when attached to a microscope, the LED array hardware allows the surgeon to correlate the focused viewing area to patient scan data, and to guide the microscope to a desired target using workstation images. 6. The technological characteristics are the same or similar to those found with the predicate device where LED systems are used to provide tracking information as an aid to surgery. {2}------------------------------------------------ Image /page/1/Picture/1 description: The image is a circular seal for the Department of Health & Human Services - USA. The seal features the department's name in a circular arrangement around the edge. In the center of the seal is an abstract emblem that resembles an eagle or a bird in flight, composed of three curved lines. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 1 1998 JUL Ms. Lisa M. Benati · Senior Regulatory Engineer Radionics Software Applications, Inc. 22 Terry Avenue Burlington, Massachusetts 01803 Re: K981213 Trade Name: Universal Instrument Registration (UIS) Microscope Module I Regulatory Class: II Product Code: HAW Dated: April 1, 1998 Received: April 2, 1998 ## Dear Ms. Benati: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {3}------------------------------------------------ Page 2 - Ms. Lisa M. Benati This letter will allow you to begin marketing your devices as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your devices to a legally marketed predicate device results in a classification for your devices and thus, permits your devices to proceed to the market. If you desire specific advice for your devices on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your devices, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ 510(k) Number (if known):___98 |2 |3 Device Name: UNIVERSAL INSTRUMENT REGISTRATION AND MICROSCOPE MODULE I ACCESSORIES TO RADIONICS' OPTICAL TRACKING SYSTEM (OTS). Indications For Use: The system accessories are indicated for all cranial and spinal surgical procedures covered by the OTS where anatomical Spinal Surgicur procedures is is where a desired target is close to critical structures. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) Division of General Restoratio: 510(k) Number K981213 Prescription Use (Per 21 CFR 801.109) OR ## Over-The-Counter Use (Option: Formst 1-7-95)
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...