ALIGN SYSTEM

K981095 · Align Technology · NXC · Sep 8, 1998 · Dental

Device Facts

Record IDK981095
Device NameALIGN SYSTEM
ApplicantAlign Technology
Product CodeNXC · Dental
Decision DateSep 8, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.5470
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Align System is indicated for the treatment of tooth malocclusion in patients with permanent dentition (i.e., all second molars). The Align System positions teeth by way of continuous gentle force.

Device Story

Align System uses series of clear plastic aligners to move teeth in small increments; replaces conventional wire/bracket orthodontics. Dental practitioner provides dental stone models and prescription; Align uses 3D laser scanning to digitize molds. Software generates final treated state and interpolates intermediate states; rapid prototyping (stereolithography) creates physical molds for each state. Conventional air pressure device (e.g., Biostar) forms plastic aligners over molds. Clinician dispenses sequential aligners to patient for wear. System provides continuous gentle force to achieve tooth movement. Used in dental clinic setting; operated by dental practitioner.

Clinical Evidence

No clinical data or bench testing performed. Safety and effectiveness supported by scientific literature regarding preformed tooth positioners.

Technological Characteristics

Series of clear plastic aligners; fabricated using commercially available retainer/positioner material via air pressure molding (e.g., Biostar). 3D laser scanning and stereolithography used for mold production. Software-assisted treatment planning.

Indications for Use

Indicated for treatment of tooth malocclusion in patients with permanent dentition (all second molars).

Regulatory Classification

Identification

An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/0/Picture/1 description: The image shows the logo for the Department of Health and Human Services, USA. The logo is circular and contains the words "DEPARTMENT OF HEALTH AND HUMAN SERVICES, USA" around the perimeter. In the center of the circle is a symbol consisting of three stylized human figures. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 MAR 2 0 2000 Align Technology, Incorporated 881 Martin Avenue Santa Clara, California 95050 Re: K981095 Trade/Device Name: Align System Regulation Number: 872.5470 Regulation Name: Orthodontic Plastic Bracket Regulatory Class: II Product Code: NXC Dated: July 30, 1998 Received: July 31, 1998 Dear Mr. Kolesar: This letter corrects our substantially equivalent letter of September 8. 1998. We are issuing this letter solely because The Align System, as described in the indication for use, is equivalent to an orthodontic plastic bracket. We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976. the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA). it may be subject to additional controls. Existing major regulations affecting vour device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA mav publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Page -2 Mr. Kolesar Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act): 21 CFR 1000-1050. This letter will allow you to continue marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours. Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ALIGN TECHNOLOGY, INC. ALIGN SYSTEM SIOK APPLICATION # INDICATIONS FOR USE K 481095 To Be Assigned By FDA 510(k) Number: Align System Device Name: The Align System is indicated for the treatment of tooth Indications For Use: malocclusion in patients with permanent dentition (i.e., all second molars). The Align System positions teeth by way of continuous gentle force. PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Runner (Division Sign-Off) Division of Dental, Infection Control, and General Hospital Devices 510(k) Number K95.1695 Prescription Use レ OR Over-The-Counter Use (Per 21 CFR 801.109) 27 {3}------------------------------------------------ ## SUMMARY OF SAFETY AND EFFECTIVENESS SECTION 19: This 510(k) summary of safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and CFR 807.92. 198 1098 ### SUBMITTER INFORMATION 19.1 | a. | Company Name: | Align Technology Inc. | | |----|--------------------------------|----------------------------------------------------------|--| | b. | Company Address: | 2991 El Camino Real, Suite 120<br>Redwood City, CA 94061 | | | c. | Company Phone:<br>Company Fax: | (650) 306-8912<br>(650) 306-8915 | | | d. | Contact Person: | Kelsey Wirth<br>President<br>Align Technology Inc. | | | e. | Date Summary Prepared: | March 20, 1998 | | # 19.2. DEVICE IDENTIFICATION | a. | Trade/Proprietary Name: | Align System | |----|-------------------------|---------------------------------------| | b. | Classification Name: | Preformed Tooth Positioner (872.5525) | #### IDENTIFICATION OF PREDICATE DEVICE 19.3 | Device | 510(k) No. | Date Cleared | |--------------------------------------------------------|----------------|----------------| | Great Lakes Orthodontics<br>Preformed Tooth Positioner | Class I Exempt | Not Applicable | | TP Orthodontics Tooth Positioner | K780619 | June 28, 1978 | | Ortho-Tain Tooth Positioner | Class I Exempt | Not Applicable | {4}------------------------------------------------ #### DEVICE DESCRIPTION 19.4 Align Technology Inc. (Align) has developed the Align System, which is a series of clear plastic appliances (Aligners) that are intended to replace conventional wire and bracket technology for many orthodontic cases. The series of Aligners moves the patient's teeth in small increments from their original state to a final, treated state. The Align System will use a computer as a tool to assist in creating a series of Aligners that represent sequential movements to generate light and consistent forces on the patient's teeth. A Dental Practitioner using the Align System diagnoses a patient, determines a treatment plan, and makes dental stone models of a patient's teeth. The Dental Practitioner then sends the molds, along with a prescription for treatment to Align. Align uses three-dimensional laser scanning technology to scan the mold into a computer. From this scanned image (which represents an untreated state) and following the Dental Practitioner's prescription, Align software generates the image of a final, treated state and then interpolates a series of images that represent intermediate teeth states. For each of these intermediate states, a rapid prototyping machine (such as a stereolithography machine) produces corresponding dental molds. In the final step, Align uses a conventional air pressure device (e.g., a Biostar) and commercially available retainer or positioner material (made by Raintree Essix or equivalent) to craft plastic Aligners to fit the developed teeth molds. The models with their corresponding Aligners are then mailed back to the Dental Practitioner. The total number of Aligners can vary from 1 to over 100 per patient, depending on the complexity of the case. The Aligners are individually identified and are dispensed to the patient by the Clinician with specific instructions for use (i.e., the Aligners are to be worn in a prescribed sequence). {5}------------------------------------------------ #### SUBSTANTIAL EQUIVALENCE 19.5 The Align Technology Inc. Align System is of comparable type and is equivalent to the Preformed Tooth Positioners manufactured by Great Lakes Orthodontics, TP Orthodontics, and Ortho-Tain. #### INTENDED USE 19.6 The Align System is indicated for the treatment of tooth malocclusion in patients with permanent dentition (i.e., all second molars). The Align System positions teeth by way of continuous gentle force. #### TECHNOLOGICAL CHARACTERISTICS 19.7 A comparison of the technological characteristics of the predicate and legally marketed devices has been performed. The results of this comparison demonstrate that the Aligners are equivalent to the currently marketed predicate devices. #### 19.8 PERFORMANCE DATA Bench testing of the Aligners has not been performed due to the difficulty in evaluating this type of dental device in a laboratory setting. However, there is sufficient information available from the scientific literature to demonstrate that the preformed tooth positioner provides reasonable assurance of safety and effectiveness. {6}------------------------------------------------ ## 510(K) CHECKLIST 19.9 This notification contains all information required by 21 CFR 807.87. A completed copy of the Premarket Notification 510(k) Reviewer's Checklist has been provided with this submission.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...