SEMKIN BIPOLAR FORCEP

K974594 · Titan Mfg., Inc. · HTD · Jun 24, 1998 · General, Plastic Surgery

Device Facts

Record IDK974594
Device NameSEMKIN BIPOLAR FORCEP
ApplicantTitan Mfg., Inc.
Product CodeHTD · General, Plastic Surgery
Decision DateJun 24, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4800
Device ClassClass 1
AttributesTherapeutic

Indications for Use

Intended to remove tissue and control bleeding by use of high frequency electrical current. (21 CFR §878.4400).

Device Story

Semkin Bipolar Forcep is a surgical instrument used to grasp tissue and deliver high-frequency electrical current for coagulation and tissue removal. Operated by surgeons in clinical or OR settings, the device functions as an electrosurgical accessory. It facilitates hemostasis by applying current directly to the target site, aiding in bleeding control during surgical procedures. The device is a manual, non-powered instrument requiring an external electrosurgical generator for energy delivery.

Clinical Evidence

Bench testing only.

Technological Characteristics

Manual bipolar electrosurgical forceps. Conductive tips for high-frequency current delivery. Designed for use with standard electrosurgical generators. Non-sterile or sterilizable construction (implied by surgical use).

Indications for Use

Indicated for tissue removal and hemostasis via high-frequency electrical current in surgical procedures.

Regulatory Classification

Identification

A manual surgical instrument for general use is a nonpowered, hand-held, or hand manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892 of this chapter.

Submission Summary (Full Text)

{1}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three lines forming its wing and head. The eagle faces to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUN 24 1998 Mr. Donald Seavey ·Titan Manufacturing, Inc. 6 Jamie Lane Phoenixville, Pennsylvania 19460 K974594 Re: Trade Name: Semkin Bipolar Forcep Regulatory Class: II Product Code: GEI Dated: March 20,1998 Received: May 27, 1998 Dear Mr. Seavey: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. {2}------------------------------------------------ Page 2 - Mr. Seavey If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, tca deefa Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ ## Titan Manufacturing, Inc. 6 Jamic Lanc Phoenixville, PA 19460 Tel/Fax: 610.933.9771 ## INDICATIONS FOR USE STATEMENT 974594 510(k) Number (if known): Device Name: Semkin Bipolar Forcep ________________________________________________________________________________________________________________________________________________________ Indications For Use: Intended to remove tissue and control bleeding by use of high frequency electrical current. (21 CFR §878.4400). (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) | Prescription Use<br>(Per 21 CFR 801.109) | X | OR | Over-The-Counter Use | | |------------------------------------------|---|----|----------------------|--| |------------------------------------------|---|----|----------------------|--| (Optional Format 1-2-96) --- (Division Sign Off) Division of General Restorative and Device | 510(k) Number | K974594 | |---------------|---------| |---------------|---------|
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...