← Product Code [LPH](/productcode/LPH) · K973714

# VERSYS HIP SYSTEM BEADED HIP PROSTHESIS (K973714)

_Zimmer, Inc. · LPH · Dec 24, 1997 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K973714

## Device Facts

- **Applicant:** Zimmer, Inc.
- **Product Code:** [LPH](/productcode/LPH.md)
- **Decision Date:** Dec 24, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3358
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The VerSys Beaded Hip Prosthesis is designed to achieve biologic fixation to bone and is indicated for: - Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis, disability due to previous fusion, previously failed endoprotheses and/or total hip components in the affected extremity, and acute femoral neck fractures. - Hemi-hip replacement for the following: fracture dislocation of the hip, elderly, debilitated patients when a total hip replacement is contraindicated, irreducible fractures in which adequate fixation cannot be obtained, certain high subcapital fractures and comminuted fractures, secondary avascular necrosis of the femoral head, pathological fractures of the femoral neck, and osteoarthritis in which the femoral head is primarily affected.

## Device Story

VerSys Beaded Hip Prosthesis is a modular, cementless femoral hip stem designed for biologic fixation via bone ingrowth. Device consists of Zimaloy (Co-Cr-Mo alloy) stem with sintered Co-Cr-Mo alloy bead porous coating. Features 12/14 Morse-type taper for attachment of modular Co-Cr-Mo or zirconia ceramic femoral heads. Available in standard and large metaphysis body options; midcoat or fullcoat porous coating lengths. Midcoat stems include distal longitudinal splines and flutes. Implanted by surgeons in clinical settings to replace diseased or damaged hip joints. Output is a stable, load-bearing femoral component that articulates with acetabular components to restore hip function, reduce pain, and improve patient mobility.

## Clinical Evidence

No clinical data provided. Substantial equivalence is supported by literature reporting satisfactory results for substantially equivalent hip prostheses and the established principle of mechanical stabilization followed by secondary biologic fixation via bone ingrowth.

## Technological Characteristics

Modular femoral stem; Zimaloy (Co-Cr-Mo alloy) substrate; sintered Co-Cr-Mo alloy bead porous coating. Trapezoidal proximal body geometry; 12/14 Morse-type taper. Available in midcoat (with distal splines/flutes) or fullcoat configurations. Cementless fixation principle.

## Regulatory Identification

A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.

## Predicate Devices

- Beta System ([K953337](/device/K953337.md))
- AML Total Hip System with Porocoat ([P820024](/device/P820024.md))
- Porocoat Porous Coating ([K931641](/device/K931641.md))
- Prodigy Hip Prosthesis ([K931641](/device/K931641.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

FM 15114

Image /page/0/Picture/1 description: The image shows the logo for Zimmer Biomet. The logo consists of a stylized letter "Z" inside of a circle, with the word "zimmer" written in lowercase letters below it. The logo is black and white and appears to be scanned from a document.

P.O. Box 708 Warsaw. IN 46581-0708 219 267-6131

# DEC 2 4 1997

## Summary of Safety and Effectiveness VerSys® Hip System Beaded Hip Prosthesis

#### Submitted By: .

Zimmer, Inc. P.O. Box 708 Warsaw, Indiana 46581-0708 219-267-6131

#### Contact Person: .

Karen Cain Specialist, Global Regulatory Affairs 219/372-4219 Telephone: 219/372-4605 Telefax:

#### Date: .

September 26, 1997

#### Trade Name: .

VerSys® Hip System Beaded Hip Prosthesis

#### Common Name: .

Femoral Hip Prosthesis

#### Classification Name: .

Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis

Image /page/0/Picture/17 description: The image contains the number 1. The number is black and is on a white background. The number is tall and thin.

Image /page/0/Picture/18 description: The image shows a geometric pattern. The pattern is made up of triangles arranged in a hexagonal shape. The triangles are oriented in different directions, creating a complex and symmetrical design.

{1}------------------------------------------------

## Predicate Devices:

- Beta System, manufactured by Zimmer, K953337, cleared January 22, 1996 -
- AML Total Hip System with Porocoat, manufactured by DePuy, P820024, approved for use without bone cement August 19, 1993, (formerly called the Porocoat Modified Austin-Moore Total Hip Prosthesis); Porocoat Porous Coating, K931641, cleared for use without bone cement March 21, 1994
- Prodigy Hip Prosthesis, manufactured by DePuy, K931641, cleared March -21, 1994

### Device Description

The VerSys Beaded Hip is a modular stem manufactured from Zimaloy® Cobalt-Chromium-Molybdenum Alloy and has a sintered Co-Cr-Mo alloy bead porous surface coating. The prosthesis features a 12/14 Morse-type taper to accommodate the attachment of modular Co-Cr-Mo alloy or zirconia ceramic femoral heads. Proximal body geometry of the VerSys Beaded Hip is trapezoidal and two body options (standard and large metaphysis) are offered in select sizes to meet patient anatomical requirements. The VerSys Beaded Hip Prosthesis is available in two porous coating length options, a midcoat option and a fullcoat option. The distal shaft of the midcoat stem has longitudinal splines. Flutes (grooves, channels) are featured on the distal anterior and posterior surfaces of the midcoat stem.

#### Indications for Use .

The VerSys Beaded Hip Prosthesis is designed to achieve biologic fixation to bone and is indicated for:

- Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis, disability due to previous fusion, previously failed endoprotheses and/or total hip components in the affected extremity, and acute femoral neck fractures.
- Hemi-hip replacement for the following: fracture dislocation of the hip, elderly, debilitated patients when a total hip replacement is contraindicated, irreducible fractures in which adequate fixation cannot be obtained, certain

{2}------------------------------------------------

high subcapital fractures and comminuted fractures, secondary avascular necrosis of the femoral head, pathological fractures of the femoral neck, and osteoarthritis in which the femoral head is primarily affected.

### Comparison to Predicate Devices

- Beta System, manufactured by Zimmer, K953337, cleared January 22, 1996 -
- AML Total Hip System with Porocoat, manufactured by DePuy, P820024, approved for use without bone cement August 19, 1993, (formerly called the Porocoat Modified Austin-Moore Total Hip Prosthesis); Porocoat Porous Coating, K931641, cleared for use without bone cement March 21, 1994
- -Prodigy Hip Prosthesis, manufactured by DePuy, K931641, cleared March 21, 1994

All hip systems listed above are substantially equivalent to each other and the VerSys Hip System Beaded Hip in that each is intended for cementless fixation into the intramedullary canal for pathological or degenerative conditions involving the femur and/or acetabulum. All predicate devices are modular in design. Each has a Morsetype proximal neck taper to accommodate the attachment of a femoral head which, in turn, articulates upon the ultra-high molecular-weight polyethylene (UHMWPE) bearing surface of a total hip or hemi-hip acetabular component.

#### Clinical Data .

One current method of femoral hip prothesis implantation relies upon mechanical fixation through initial implant stabilization with secondary fixation supplied by bone ingrowth. The VerSys Hip System Beaded Stem is an example of a device designed to achieve biologic fixation to bone without the use of bone cement. Many studies published in the literature report that satisfactory results have been obtained with the use of hip prostheses that are substantially equivalent to the VerSys Beaded Hip Prosthesis.

RA09702K.510

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized image of an eagle with three heads, representing the department's mission to protect the health of all Americans and provide essential human services. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" are arranged in a circular pattern around the eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

DEC 2 4 1997

Ms. Karen Cain Requlatory Affairs Specialist Zimmer P.O. Box 708 Warsaw, Indiana 46581-0708

Re: K973714 VERSYS® Hip System Beaded Hip Prosthesis Trade Name: Regulatory Class: II Product Codes: LPH and LZO Dated: September 26, 1997 Received: September 29, 1997

Dear Ms. Cain:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Requlation (QS) for Medical General regulation (21 CFR Part 820) and that, Devices: through periodic (OS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory In addition, FDA may publish further announcements action. concerning your device in the Federal Reqister. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or requlations.

{4}------------------------------------------------

Paqe 2 - Ms. Karen Cain

This letter will allow you to beqin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diaqnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to
premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.qov/cdrh/dsmamain.html".

Sincerely yours,

sincerely yours,

Alan Watt

Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radioloqical Health

Enclosure

{5}------------------------------------------------

Exhibit M

Page __ 1 __ of ___ 1 __

510(k) Number (if known): K973714

Device Name: VerSys® Hip System Beaded Hip Prosthesis

Indications for Use:

The VerSys Beaded Hip Prosthesis is designed to achieve biologic fixation to bone and is indicated for:

- Total hip replacement for the following: severe hip pain and disability due to ア rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis, disability due to previous fusion, previously failed endoprotheses and/or total hip components in the affected extremity, and acute femoral neck fractures.
- Hemi-hip replacement for the following: fracture dislocation of the hip, elderly, debilitated patients when a total hip replacement is contraindicated, irreducible fractures in which adequate fixation cannot be obtained, certain high subcapital fractures and comminuted fractures, secondary avascular necrosis of the femoral head, pathological fractures of the femoral neck, and osteoarthritis in which the femoral head is primarily affected.

## (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

| Concurrence of CDRH, Office of Device Evaluation (ODE) |  |
|--------------------------------------------------------|--|
|                                                        |  |
|                                                        |  |

(Division Sign-Off) Division of General Restorative Devices 510(k) Number K973714

Prescription Use X (Per 21 CFR 801.109)

(Optional Format 1-2-96)

Over The-Counter Use _________________________________________________________________________________________________________________________________________________________

RA02650K.FM

---

**Source:** [https://fda.innolitics.com/device/K973714](https://fda.innolitics.com/device/K973714)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
