CERTODYN RAECG UNIVERSAL ADAPTER

K973371 · B.Braun Medical, Inc. · DQY · Nov 24, 1997 · Cardiovascular

Device Facts

Record IDK973371
Device NameCERTODYN RAECG UNIVERSAL ADAPTER
ApplicantB.Braun Medical, Inc.
Product CodeDQY · Cardiovascular
Decision DateNov 24, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1250
Device ClassClass 2

Indications for Use

in the accurate placement of central venous catheters using the RAECG technique

Device Story

The Certodyn RAECG Universal Adapter is a device designed to aid in the accurate placement of central venous catheters. It utilizes the RAECG (Right Atrial Electrocardiogram) technique to assist clinicians during catheter insertion. The device acts as an interface to facilitate the monitoring of ECG signals during the procedure, allowing the healthcare provider to confirm the catheter tip position. It is intended for use in a clinical setting by trained medical professionals.

Clinical Evidence

No clinical data provided; bench testing only. Finished products undergo physical testing and visual examination in accordance with Quality Control Test Procedure documents and GMP requirements.

Technological Characteristics

The device is an adapter for RAECG catheter placement. Materials have been tested in accordance with Tripartite Guidance for Plastics. The device is a passive electrical interface component.

Indications for Use

Indicated for use in the accurate placement of central venous catheters using the RAECG technique.

Regulatory Classification

Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K973371 NOV 2 4 1997 # II. 510(k) SUMMARY of SAFETY and EFFECTIVENESS in ACCORDANCE with SMDA'90 B. Braun Medical, Inc 1997 824 Twelfth Avenue Bethlehem, PA 18018 (610)691-5400 Contact: Mark S. Alsberge, Regulatory Affairs Director Product Name: Epidural Catheter Connector Trade Name: Conduction Anesthesia Kit #### Classification Name: Cardiovascular Class II, 74 DQY, Percutaneous Catheter 21 CFR 870.1250 # Substantial Equivalence to: | 510(k) number | Name | Applicant | |---------------|--------------------------|---------------------------| | K843263 | Arrow-Johans ECG Adaptor | Arrow International, Inc. | #### Device Description: In accordance with section 510(k) for the Federal Food, Drug, and Cosmetic Act, B. Braun Medical, Inc. intends to introduce into interstate commerce the Certodyn® RAECG Universal Adapter. The Adapter is designed to aid in the accurate placement of central venous catheters using the RAECG technique. The term "substantially equivalent" as use herein is intended to be a determination of substantial equivalence from an FDA -regulatory point of view under the Federal Food, Drug, and Cosmetic Act and relates to the fact that the product can be marketed without premarket approval or reclassification. These products may be considered distinct from a patent point of view. The term "substantially equivalent" is not applicable to and does not diminish any patent claims related to this product or the technology used to manufacture the product. {1}------------------------------------------------ ### Materials: The Certodyn® RAECG Universal Adapter is composed of materials that have been tested in accordance with Tripartite Guidance for Plastics and determined to be suitable for the intended use of this product. #### Substantial Equivalence: The Certodyn® RAECG Universal Adapter is equivalent in materials, form, and intended use to our the Arrow-Johans ECG Adaptor currently marketed under K843263 by Arrow International, Inc. There are no new issues of safety or effectiveness raised by the Certodyn® RAECG Universal Adapter. ### Safety and Effectiveness: All finished products are tested and must meet all required release specifications before distribution. The array of testing required for release include, but are not limited to; physical testing, visual examination (in process and finished product). The physical testing is defined by Quality Control Test Procedure documents. These tests are established testing procedures and parameters which conform to the product design specifications. The testing instruction records for each of the individually required procedures are approved, released, distributed and revised in accordance with document control GMP"s. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three stripes forming its body and wings. The eagle is positioned within a circle that contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20856 NOV 2 4 1997 Mr.. Mark S. Alsberge Director, Regulatory Affairs B. Braun Medical, Inc. 824 12th Avenue Bethlehem, PA 18018-0027 Re: K973371 Trade Name: Certodyn RAECG Universal Adapter Regulatory Class: II ... Product Code: DOY Dated: September 3, 1997 Received: September 8, 1997 Dear Mr. Alsberge: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {3}------------------------------------------------ Page 2 - Mr. Mark S. Alsberge This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "dsmo@fdadr.cdrh.fda.gov". Sincerely yours, Thomas J. Callahan Thomas J. Callahan, Ph.D. Director Division of Cardiovascular, Respiratory, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ - K923321 - -510(k) Number (if known): Device Name: Certody n RAEC G Universal Adapter Indications For Use: in the accurate placement of central aid ﺍﻟﻤ catheters using the RAECG technique Venous (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) Division of Cardiovascular, and Neurological Devices 510(k) Number K973371 Prescription Use X (Per 21 CFR 801.109) OR Over-The-Counter Use (Optional Format 1-2-96)
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...