Antimicrobial Susceptibility Test Discs are indicated for the semi-quantitative susceptibility testing by agar diffusion test procedure of rapidly growing micro-organisms. These include : Staphylococcus spp., and modified by procedures, Haemophilus influenzae.
Device Story
Oxoid Rifampicin Antimicrobial Susceptibility Test Disc is an in vitro diagnostic device used in clinical microbiology laboratories. The device consists of paper discs impregnated with a specific concentration of the antibiotic Rifampicin. In the agar diffusion test procedure, the disc is placed on an agar plate inoculated with a patient's bacterial isolate. As the antibiotic diffuses into the agar, it creates a concentration gradient. The device facilitates the measurement of the zone of inhibition around the disc, which is used to determine the susceptibility of the microorganism to the antibiotic. Results are interpreted by laboratory professionals to guide clinicians in selecting appropriate antimicrobial therapy for patients with bacterial infections. The device aids in managing patient care by providing data on bacterial resistance patterns.
Clinical Evidence
No clinical data provided; device relies on established agar diffusion susceptibility testing principles.
Technological Characteristics
Paper disc impregnated with Rifampicin; utilizes agar diffusion principle for antimicrobial susceptibility testing; in vitro diagnostic use.
Indications for Use
Indicated for semi-quantitative susceptibility testing of rapidly growing microorganisms, specifically Staphylococcus spp. and Haemophilus influenzae (via modified procedures), using agar diffusion methods.
Regulatory Classification
Identification
An antimicrobial susceptibility test disc is a device that consists of antimicrobic-impregnated paper discs used to measure by a disc-agar diffusion technique or a disc-broth elution technique the in vitro susceptibility of most clinically important bacterial pathogens to antimicrobial agents. In the disc-agar diffusion technique, bacterial susceptibility is ascertained by directly measuring the magnitude of a zone of bacterial inhibition around the disc on an agar surface. The disc-broth elution technique is associated with an automated rapid susceptibility test system and employs a fluid medium in which susceptibility is ascertained by photometrically measuring changes in bacterial growth resulting when antimicrobial material is eluted from the disc into the fluid medium. Test results are used to determine the antimicrobial agent of choice in the treatment of bacterial diseases.
Related Devices
K971638 — CLARITHROMYCIN ANTIMICROBIAL SUSCEPTIBILITY TEST DISC · Oxoid , Ltd. · Aug 20, 1997
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized design featuring three abstract human figures or profiles facing to the right, with flowing lines above them.
Food and Drug Administration 2098 Gaither Road Rockville MD 20850
JAN 28 1998
Andy Hollingsworth Quality Systems Manager Oxoid Limited Wade Road Basingstoke Hants RG24 8PW England
Re: K971636
> Trade Name: Oxoid Refampicin Antimicrobial Susceptibility Test Disc Regulatory Class: II Product Code: JTN Dated: November 17, 1997 Received: November 20, 1997
Dear Mr. Hollingsworth:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal Laws or Regulations.
{1}------------------------------------------------
Page 2
Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88), this device may require a CLIA complexity categorization. To determine if it does, you should contact the Centers for Disease Control and Prevention (CDC) at (770)488-7655.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll free number (800) 638-2041 or at (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html"
Sincerely yours,
Steven Gutman
Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## 510(K) Submission for Oxoid Antimicrobial Susceptibility Test Disc
## RIFAMPIN
## OXOID LTD
510(K) Number : K971636
Oxoid Rifampicin Susceptibility Test Disc Device Name :
## Indication for Use :
Antimicrobial Susceptibility Test Discs are indicated for the semi-quantitative susceptibility testing by agar diffusion test procedure of rapidly growing micro-organisms. These include : Staphylococcus spp., and modified by procedures, Haemophilus influenzae.
The technical product insert details the Quality Control organisms to be use with this disc.
Rahme Alurichy for John Ticchiust
(Division Sign-Off)
Division of Clinical Laboratory Devices
John Ticchiust MD.
Interim Slick Micinist CBR
510(k) Number __ 1 - 9 -
lin McMurrer mis.
Interim Chief, Midwest
1/26/98
Prescription Use (Per 21 CFR 801.109)
OR
Over-The Counter Use
(Optional Format 1-2-96)
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.