EVI SUTURED-CLIP APPLIER

K971588 · Elective Vascular Intervention Inc. (Evi) · FZP · Oct 24, 1997 · General, Plastic Surgery

Device Facts

Record IDK971588
Device NameEVI SUTURED-CLIP APPLIER
ApplicantElective Vascular Intervention Inc. (Evi)
Product CodeFZP · General, Plastic Surgery
Decision DateOct 24, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4300
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Elective Vascular Intervention (EVI) Sutured-Clip™ and Clip Applier is intended for use in endoscopic and non-endoscopic creation and repair of arteriovenus fistulae and the creation of everting anastomoses in blood vessels, grafts and other tubular structures and in the approximation of other soft tissue structures.

Device Story

Single-fire applier for EVI Sutured-Clips™; used for vascular anastomosis and tissue approximation. Device features vascular clip with swaged needle on one end to facilitate precise placement prior to closure. Operated by clinicians in endoscopic or non-endoscopic settings. Provides mechanical tissue approximation; needle allows precise positioning similar to traditional suture needles. Benefits include precise clip placement for vascular repair and fistula creation.

Clinical Evidence

Bench testing only. Evaluation included mechanical integrity and force required to open or dislodge clips. All results met internal specifications and predicate performance standards.

Technological Characteristics

Single-fire mechanical clip applier. Fabricated from medical and implantable grade materials. Features a vascular clip with a swaged needle. Manual operation. No software or electronic components.

Indications for Use

Indicated for endoscopic and non-endoscopic creation of everting anastomoses in blood vessels, grafts, and other tubular structures; also for repair of arteriovenous fistulae and approximation of soft tissue structures.

Regulatory Classification

Identification

An implantable clip is a clip-like device intended to connect internal tissues to aid healing. It is not absorbable.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ <171588 This summary of 510(k) safety and effectiveness information is submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92. 510(k) Number: K971588 #### Applicant Information: | Date Prepared: | April 28, 1997 | |-------------------|--------------------------------------------------------| | Name: | Elective Vascular Intervention EVI) | | Address: | 2915 McClure<br>Oakland, California 94609 510-834-1210 | | Contact Person: | Michael A. Daniel | | Phone Number: | (415) 237-7036 | | Facsimile Number: | (415) 526-2060 | ### Device Information: | Classification: | Class I (Exempt) Clip Applier | |----------------------|-------------------------------------------------------------------| | | Class II Implantable Clips | | Trade Name: | EVI Sutured-Clip™ Applier | | | EVI Sutured-Clip™ | | Common Name: | Implantable Clip, Vascular Clip, Vascular/Hemostatic Clip Applier | | Classification Name: | Surgical Devices: Implantable Clip, 21 CFR 878.4300 | | | Cardiovascular Prosthetic Devices: Vascular Clip, 870.3250 | ## Predicate Devices: The Elective Vascular Intervention (EVI) Sutured-Clip™ and Sutured-Clip™ Applier is substantially equivalent in intended use and/or method of operation to a combination of the following predicate devices: | | Pilling Weck | Hemoclip S15 Automatic Applier | |----|---------------|----------------------------------| | 1. | U.S. Surgical | ENDO CLIP Applier | | 2. | Ethicon | LIGACLIP Endoscopic Clip Applier | #### Device Description: The Elective Vascular Intervention (EVI) Sutured-Clip™ and Clip Applier is a single fire applier that applies EVI Sutured-Clips™ for vascular anastomsis and tissue approximation applications. The Sutured-Clip consists of a vascular clip with a needle swaged or connected to one end. This design allows precise placement of clips prior to closure. The device is fabricated from standard medical and implantable grade materials. {2}------------------------------------------------ # 510(k) SUMMARY ## (Continued) ### Intended Use: The Elective Vascular Intervention (EVI) Sutured-Clip™ and Clip Applier is intended for use in endoscopic and non-endoscopic creation and repair of arteriovenus fistulae and the creation of everting anastomoses in blood vessels, grafts and other tubular structures and in the approximation of other soft tissue structures. #### Comparison to Predicate Device(s): The Elective Vascular Intervention (EVI) Sutured-Clip™ Clip and Clip Applier are substantially equivalent to the US Surgical VCS Clip and Clip Applier in terms of intended use. Both devices are intended for application of vascular clips to everted tissue for purposes of performing vacular anastomosis. The EVI Sutured-Clip and Clip Applier is substantially equivalent to the Ethicon LIGACLIP Clip and Clip Applier in terms of the single clip application option. The System differs from the currently marketed predicate devices in that the Sutured-Clips™ have a needle swaged on to one end to facilitate precise placement. In this regard it is similar to currently marketed suture needles. #### In Vitro Test Data: Design analysis and in vitro data confirm that basic functional characteristics are substantially equivalent to the predicate devices sited. Testing included evaluation of mechanical integrity and the force required to open or dislodge clip. All data fell within both internal specification requirements as well as external standard requirements and predicate performance expectations. #### Summary: Based upon the product technical information provided, intended use, performance and biocompatibility information provided in this pre-market notification, the EVI Sutured-Clip™ and Sutured-Clip™ Applier has been shown to be substantially equivalent to currently marketed predicate devices. {3}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles a stylized caduceus or a family of three people. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 OCT 2 4 1997 Mr. Michael A. Daniel EVI Elective Vascular Intervention 2915 McClure Oakland, California 94609 Re: K971588 Trade Name: EVI Sutured-Clip™ and Sutured-Clip™ Applier Regulatory Class: II Product Code: FZP Dated: September 14, 1997 Received: September 17, 1997 Dear Mr. Daniel: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements , as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {4}------------------------------------------------ ### Page 2 - Mr. Michael A. Daniel This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely vours, Sincerely, yours, Colin McWhirter, Ph.D., M.D. Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ K971588 510(k) Number (if known): Elective Vacular Intervention (EVI) Sutured-Clip™ Applier Device Name: ### Indications For Use: The Elective Vascular Intervention (EVI) Sutured-Clip™ and Sutured-Clip Applier™ are intended for endoscopic and non-endoscopic use in the creation of everting anastomoses in blood vessels, grafts and other tubular structures. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) | (Division Sign-Off) | | |-----------------------------------------|---------| | Division of General Restorative Devices | | | 510(k) Number | K971588 | | Prescription Use<br>(Per 21 CFR 801.109) | OR | Over-The-Counter Use ______ | |------------------------------------------|----|-----------------------------| |------------------------------------------|----|-----------------------------| (Optional Format 1-2-96)
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...