← Product Code [FLL](/productcode/FLL) · K971045

# BASIS FLEXIBLE TIP DIGITAL THERMOMETER (K971045)

_Polymedica Industries, Inc. · FLL · May 2, 1997 · General Hospital · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K971045

## Device Facts

- **Applicant:** Polymedica Industries, Inc.
- **Product Code:** [FLL](/productcode/FLL.md)
- **Decision Date:** May 2, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.2910
- **Device Class:** Class 2
- **Review Panel:** General Hospital
- **Attributes:** Pediatric

## Indications for Use

The Basis® Flexible Tip Digital Thermometer is a clinical thermometer intended for the determination of oral, rectal and axillary body temperature determination in humans.

## Device Story

Digital thermometer with flexible tip; measures human body temperature via oral, rectal, or axillary sites. Device utilizes electronic sensing technology to determine temperature; provides digital readout for clinician or patient use. Intended for intermittent temperature monitoring; aids in clinical assessment of patient health status.

## Clinical Evidence

Bench testing only; device conforms to ASTM E1112 Standard Specification for Electronic Thermometer for Intermittent Determination of Patient Temperature.

## Technological Characteristics

Electronic thermometer; flexible tip design; conforms to ASTM E1112 standards. Digital display output.

## Regulatory Identification

A clinical electronic thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electronic signal amplification, conditioning, and display unit. The transducer may be in a detachable probe with or without a disposable cover.

## Special Controls

(1) Device is not a clinical thermometer with telethermographic functions; 
(2) Device is not a clinical thermometer with continuous temperature measurement functions; and 
(3) Appropriate analysis and testing (such as that outlined in the currently FDA-recognized editions, as appropriate, of ISO 80601-2-56, “Medical electrical equipment—Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement,” or ASTM E1965, “Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature,” or ASTM E1112, “Standard Specification for Electronic Thermometer for Intermittent Determination of Patient Temperature,” or ASTM E1104, “Standard Specification for Clinical Thermometer Probe Covers and Sheaths”) must validate specifications and performance of the device.

## Predicate Devices

- Basis® Digital Thermometer (PolyMedica Industries, Inc.)
- Becton Dickinson Flexible™ Digital Thermometer

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K971045

510(k) Basis® Flexible Tip Digital Thermometer
PolyMedica Industries, Inc.

MAY - 2 1997

510(k) Summary

Proprietary Name: Basis® Flexible Tip Digital Thermometer

Common Name: Digital Thermometer with Flexible Tip

Classification: Class II

Submitter Details: PolyMedica Industries, Inc.
581 Conference Place
Golden, CO 80401
Tel: (303)271-0300
Fax: (303)271-0163
Contact: Ms. Susan Collins

The Basis® Flexible Tip Digital Thermometer is a clinical thermometer intended for the determination of oral, rectal and axillary body temperature determination in humans.

In terms of physical requirements and operating parameters, the thermometer conforms to ASTM E1112, "Standard Specification for Electronic Thermometer for Intermittent Determination of Patient Temperature".

Basis® Flexible Tip Digital Thermometer is substantially equivalent to PolyMedica Industries, Inc's Basis® Digital Thermometer and the Becton Dickinson Flexible™ Digital Thermometer.

53

---

**Source:** [https://fda.innolitics.com/device/K971045](https://fda.innolitics.com/device/K971045)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
